Appendix A—Abbreviated Register Listing

63230-300-212

Register Listing

April 2001

 

 

Table A–4:Abbreviated Register List for I/O Status

Register

Name

Units

Range

 

Description

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IO Point Type to digital Output

 

 

 

 

First digit (2) indicates point is digital output.

 

 

 

 

Second digit indicates module type

 

 

 

 

0

= Generic digital output

Base

IO Point Type

200 to 299

1 = DO120AC Pluggable Module

 

 

 

 

2

= DO200DC Pluggable Module

 

 

 

 

3

= DO240AC Pluggable Module

 

 

 

 

4

= DO60DC Pluggable Module Third digit indicates output type

 

 

 

 

1

= solid state relay

 

 

 

 

2

= electromechanical relay

 

 

 

 

 

 

Base + 1

IO Point Label

Alpha-

16-character label

Numeric

 

 

 

 

 

 

 

 

 

 

 

 

 

 

digital Output Operating Mode

 

 

 

 

0

= Normal (default)

 

 

 

 

1

= Latched

 

 

 

 

2

= Timed

 

 

 

 

3

= Absolute kWh pulse

 

 

 

 

4

= Absolute kVARh pulse

Base + 9￿

Mode

0 to 11

5 = kVAh pulse

 

 

 

 

6

= kWh In pulse

 

 

 

 

7

= kVARh In pulse

 

 

 

 

8

= kWh out pulse

 

 

 

 

9

= kVARh out pulse

 

 

 

 

10 = Register-based pulse (future)

 

 

 

 

11 = End of power demand interval

 

 

 

 

 

Base + 10

On Time For Timed

Seconds

1 to 32,767

The time for the output to remain energized when the output is in

Mode

timed mode or end of power demand interval. (Default = 1)

￿

 

 

 

 

 

 

 

 

 

KWH/

 

 

 

 

 

Pulse

 

 

 

 

 

kVarH/

 

Specifies the kWh, kVARh and kVAh per pulse for output when in

Base + 11

Pulse Weight

Pulse

1 to 32,767

these modes. (Default = 1)

 

 

kVAH/

 

 

 

 

 

 

 

 

Pulse in

 

 

 

 

 

100ths

 

 

 

 

 

 

 

 

 

Internal/External

 

 

Indicates active output state.

Base + 12

0 to 1

0 = Internal Control

Control

 

 

 

1

= External Control (default)

 

 

 

 

 

 

 

 

 

 

ControlNormal/Override

 

 

Indicates active output state.

Base + 13￿

0 to 1

0 = Normal Control (default)

 

 

 

 

1

= Override Control

 

 

 

 

 

 

 

 

 

IO Point Diagnostic Bitmap:

 

 

 

 

0

= OK, 1 = Error

 

 

 

 

Bit 00 = IO Point diagnostic summary

 

 

 

 

Bit 01 = Configuration invalid to default value used

Base + 22

IO Point Diagnostic

0x0000 to

Bit 02 = digital output energy pulse to time between transitions

Bitmap

0x000F

exceeds 30 seconds

 

 

 

 

 

 

Bit 03 = digital output energy pulse to time between transitions

 

 

 

 

limited to 20 milliseconds

 

 

 

 

Remaining bits not used.

 

 

 

 

 

 

Base + 25

Digital Output On/Off

0 to 1

digital output Off/On status: 0 = Off, 1 = On

Status

 

 

 

 

 

 

 

 

 

 

 

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup

￿￿mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions

on how to use the setup-mode commands.© 2001 Schneider Electric All Rights Reserved170