Appendix A—Abbreviated Register Listing

63230-300-212

Register Listing

April 2001

 

 

Table A–3:Abbreviated Register List

Register

Description

Scale

Units

Register Range

Number

Factor

 

 

 

 

 

 

 

 

1693

Maximum Voltage, Negative Sequence, Angle

0.1

0 to 3,599

 

 

 

 

 

1694

Maximum Voltage, Zero Sequence, Magnitude

D

Volts/Scale

0 to 32,767

 

 

 

 

 

1695

Maximum Voltage, Zero Sequence, Angle

0.1

0 to 3,599

 

 

 

 

 

1696

Maximum Current, Sequence, Unbalance

0.10%

-1,000 to 1,000

 

 

 

 

 

1697

Maximum Voltage, Sequence, Unbalance

0.10%

-1,000 to 1,000

 

 

 

 

 

Accumulated Energy

 

 

 

 

 

 

 

 

1700 to 1703

Energy, Real In

WH

0 to 9,999,999,999,999,999

 

 

 

 

 

1704 to 1707

Energy, Reactive In

VArH

0 to 9,999,999,999,999,999

 

 

 

 

 

1708 to 1711

Energy, Real Out

WH

0 to 9,999,999,999,999,999

 

 

 

 

 

1712 to 1715

Energy, Reactive Out

VArH

0 to 9,999,999,999,999,999

 

 

 

 

 

1716 to 1719

Energy, Real Total (signed/absolute)

WH

-9,999,999,999,999,999 to

9,999,999,999,999,999

 

 

 

 

 

 

 

 

 

1720 to 1723

Energy, Reactive Total (signed/absolute)

VArH

-9,999,999,999,999,999-

9,999,999,999,999,999

 

 

 

 

 

 

 

 

 

1724 to 1727

Energy, Apparent

VAH

0 to 9,999,999,999,999,999

 

 

 

 

 

1728 to 1731

Energy, Conditional Real In

WH

0 to 9,999,999,999,999,999

 

 

 

 

 

1732 to 1735

Energy, Conditional Reactive In

VArH

0 to 9,999,999,999,999,999

 

 

 

 

 

1736 to 1739

Energy, Conditional Real Out

WH

0 to 9,999,999,999,999,999

 

 

 

 

 

1740 to 1743

Energy, Conditional Reactive Out

VArH

0 to 9,999,999,999,999,999

 

 

 

 

 

1744 to 1747

Energy, Conditional Apparent

VAH

0 to 9,999,999,999,999,999

 

 

 

 

 

1748 to 1750

Energy, Incremental Real In, Last Complete Interval

WH

0 to 999,999,999,999

 

 

 

 

 

1751 to 1753

Energy. Incremental Reactive In, Last Complete Interval

VArH

0 to 999,999,999,999

 

 

 

 

 

1754 to 1756

Energy, Incremental Real Out, Last Complete Interval

WH

0 to 999,999,999,999

 

 

 

 

 

1757 to 1759

Energy, Incremental Reactive Out, Last Complete Interval

VArH

0 to 999,999,999,999

 

 

 

 

 

1760 to 1762

Energy, Incremental Apparent, Last Complete Interval

VAH

0 to 999,999,999,999

 

 

 

 

 

1763 to 1766

Last Complete Interval Date/Time

See template

See template

 

 

 

 

 

1767 to 1769

Energy, Incremental Real In, Present Interval

WH

0 to 999,999,999,999

 

 

 

 

 

1770 to 1772

Energy. Incremental Reactive In, Present Interval

VArH

0 to 999,999,999,999

 

 

 

 

 

1773 to 1775

Energy, Incremental Real Out, Present Interval

WH

0 to 999,999,999,999

 

 

 

 

 

1776 to 1778

Energy, Incremental Reactive Out, Present Interval

VArH

0 to 999,999,999,999

 

 

 

 

 

1779 to 1781

Energy, Incremental Apparent, Present Interval

VAH

0 to 999,999,999,999

 

 

 

 

 

1782 to 1784

Energy, Reactive, Quadrant 1

VArH

0 to 999,999,999,999

 

 

 

 

 

1785 to 1787

Energy, Reactive, Quadrant 2

VArH

0 to 999,999,999,999

 

 

 

 

 

1788 to 1790

Energy, Reactive, Quadrant 3

VArH

0 to 999,999,999,999

 

 

 

 

 

1791 to 1793

Energy, Reactive, Quadrant 4

VArH

0 to 999,999,999,999

 

 

 

 

 

1794

Conditional Energy Control Status

0 = OFF

1 = ON

 

 

 

 

 

 

 

 

 

See “How Power Factor is Stored in the Register” on page 128.

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.

144

© 2001 Schneider Electric All Rights Reserved

Page 156
Image 156
Schneider Electric 4000 manual Accumulated Energy, 144