63230-300-212

Appendix A—Abbreviated Register Listing

April 2001

Register Listing

 

 

Table A–3:Abbreviated Register List

Register

Description

Scale

Units

Register Range

Number

Factor

 

 

 

 

 

 

 

 

 

 

1372

Minimum Alternate Displacement Power Factor, Phase A

0.001

0 to 2,000

 

 

 

 

 

 

 

1373

Minimum Alternate Displacement Power Factor, Phase B

0.001

0 to 2,000

 

 

 

 

 

 

 

1374

Minimum Alternate Displacement Power Factor, Phase C

0.001

0 to 2,000

￿

 

 

 

 

 

1375

Minimum Alternate Displacement Power Factor, Total

0.001

0 to 2,000 ￿

 

 

 

 

 

1380

Minimum Frequency

0.01 Hertz

(50/60) 2,300 to 6,700

0.1 Hertz

(400) 3,500 to 4,500

 

 

 

 

 

 

 

 

1381

Minimum Temperature

0.1 °C

-1,000 to 1,000

 

 

 

 

 

 

1390

Minimum Auxiliary Analog Input Value, User-Selected Input 1

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1391

Minimum Auxiliary Analog Input Value, User-Selected Input 2

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1392

Minimum Auxiliary Analog Input Value, User-Selected Input 3

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1393

Minimum Auxiliary Analog Input Value, User-Selected Input 4

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1394

Minimum Auxiliary Analog Input Value, User-Selected Input 5

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1395

Minimum Auxiliary Analog Input Value, User-Selected Input 6

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1396

Minimum Auxiliary Analog Input Value, User-Selected Input 7

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1397

Minimum Auxiliary Analog Input Value, User-Selected Input 8

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1398

Minimum Auxiliary Analog Input Value, User-Selected Input 9

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1399

Minimum Auxiliary Analog Input Value, User-Selected Input 10

Refer to Analog Input

-32,767 to 32,767

Setup

 

 

 

 

 

 

 

 

 

 

 

1400

Minimum THD/thd Current, Phase A

0.10%

0 to 32,767

 

 

 

 

 

 

 

1401

Minimum THD/thd Current, Phase B

0.10%

0 to 32,767

 

 

 

 

 

 

 

1402

Minimum THD/thd Current, Phase C

0.10%

0 to 32,767

 

 

 

 

 

 

 

1403

Minimum THD/thd Current, Phase N

0.10%

0 to 32,767

 

 

 

 

 

 

 

1404

Minimum THD/thd Current, Ground

0.10%

0 to 32,767

 

 

 

 

 

 

 

1407

Minimum THD/thd Voltage, A-N

0.10%

0 to 32,767

 

 

 

 

 

 

 

1408

Minimum THD/thd Voltage, B-N

0.10%

0 to 32,767

 

 

 

 

 

 

 

1409

Minimum THD/thd Voltage, C-N

0.10%

0 to 32,767

 

 

 

 

 

 

 

1410

Minimum THD/thd Voltage, N-G

0.10%

0 to 32,767

 

 

 

 

 

 

 

1411

Minimum THD/thd Voltage, A-B

0.10%

0 to 32,767

￿

1412

Minimum THD/thd Voltage, B-C

0.10%

0 to 32,767

 

 

 

 

 

 

 

1413

Minimum THD/thd Voltage, C-A

0.10%

0 to 32,767

 

 

 

 

 

 

 

1418

Minimum Current K-Factor, Phase A

0.10

0 to 10,000

 

 

 

 

 

 

 

See “How Power Factor is Stored in the Register” on page 128.

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.

© 2001 Schneider Electric All Rights Reserved