Appendix A—Abbreviated Register Listing

63230-300-212

Register Listing

April 2001

 

 

Table A–3:Abbreviated Register List

Register

Description

Scale

Units

Register Range

Number

Factor

 

 

 

 

 

 

 

 

1231

Current Fundamental Coincident Angle, Phase A

0.1 °

0 to 3,599

 

 

 

 

 

1232

Current Fundamental RMS Magnitude, Phase B

A

Amps/Scale

0 to 32,767

 

 

 

 

 

1233

Current Fundamental Coincident Angle, Phase B

0.1 °

0 to 3,599

 

 

 

 

 

1234

Current Fundamental RMS Magnitude, Phase C

A

Amps/Scale

0 to 32,767

 

 

 

 

 

1235

Current Fundamental Coincident Angle, Phase C

0.1 °

0 to 3,599

 

 

 

 

 

1236

Current Fundamental RMS Magnitude, Neutral

B

Amps/Scale

0 to 32,767

 

 

 

 

 

1237

Current Fundamental Coincident Angle, Neutral

0.1 °

0 to 3,599

 

 

 

 

 

1238

Current Fundamental RMS Magnitude, Ground

C

Amps/Scale

0 to 32,767 ￿

 

 

 

 

 

1239

Current Fundamental Coincident Angle, Ground

0.1 °

0 to 3,599 ￿

 

 

 

 

 

1244

Voltage Fundamental RMS Magnitude, A-N/A-B

D

Volts/Scale

0 to 32,767

 

 

 

 

 

1245

Voltage Fundamental Coincident Angle, A-N/A-B

0.1 °

0 to 3,599

 

 

 

 

 

1246

Voltage Fundamental RMS Magnitude, B-N/B-C

D

Volts/Scale

0 to 32,767

 

 

 

 

 

1247

Voltage Fundamental Coincident Angle, B-N/B-C

0.1 °

0 to 3,599

 

 

 

 

 

1248

Voltage Fundamental RMS Magnitude, C-N/C-A

D

Volts/Scale

0 to 32,767

 

 

 

 

 

1249

Voltage Fundamental Coincident Angle, C-N/C-A

0.1 °

0 to 3,599

 

 

 

 

 

1250

Voltage Fundamental RMS Magnitude, N-G

E

Volts/Scale

0 to 32,767

 

 

 

 

 

1251

Voltage Fundamental Coincident Angle, N-G

0.1 °

0 to 3,599 ￿

 

 

 

 

 

1255

Fundamental Real Power, Phase A

F

kW/Scale

-32,767 to ￿32,767

 

 

 

 

 

1256

Fundamental Real Power, Phase B

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1257

Fundamental Real Power, Phase C

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1258

Fundamental Real Power, Total

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1259

Fundamental Reactive Power, Phase A

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

1260

Fundamental Reactive Power, Phase B

F

kVAr/Scale

-32,767 to 32,76

 

 

 

 

 

1261

Fundamental Reactive Power, Phase C

F

kVAr/Scale

-32,767 to 32,767￿

 

 

 

 

 

1262

Fundamental Reactive Power, Total

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

1264

Distortion Power, Phase A

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1265

Distortion Power, Phase B

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1266

Distortion Power, Phase C

F

kW/Scale

-32,767 to 32,767 ￿

 

 

 

 

 

1267

Distortion Power, Total

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

1268

Distortion Power Factor, Phase A

0.10%

0 to 1,000

 

 

 

 

 

1269

Distortion Power Factor, Phase B

0.10%

0 to 1,000

 

 

 

 

 

1270

Distortion Power Factor, Phase C

0.10%

0 to 1,000 ￿

1271

Distortion Power Factor, Total

0.10%

0 to 1,000

 

 

 

 

 

1274

Harmonic Current, Phase A

A

Amps/Scale

0 to 32,767

 

 

 

 

 

1275

Harmonic Current, Phase B

A

Amps/Scale

0 to 32,767

 

 

 

 

 

1276

Harmonic Current, Phase C

A

Amps/Scale

0 to 32,767

 

 

 

 

 

See “How Power Factor is Stored in the Register” on page 128.

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.

134

© 2001 Schneider Electric All Rights Reserved

Page 146