Appendix A—Abbreviated Register Listing

63230-300-212

Register Listing

April 2001

 

 

Table A–3:Abbreviated Register List

Register

Description

Scale

Units

Register Range

 

Number

Factor

 

 

 

 

 

 

 

 

 

 

 

 

1144

Reactive Power, Phase A

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1145

Reactive Power, Phase B

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1146

Reactive Power, Phase C

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1147

Reactive Power, Total

F

kVAr/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1148

Apparent Power, Phase A

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1149

Apparent Power, Phase B

F

kVA /Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1150

Apparent Power, Phase C

F

kVA /Scale

-32,767 to 32,767 ￿

 

 

 

 

 

 

 

1151

Apparent Power, Total

F

kVA /Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1160

True Power Factor, Phase A

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1161

True Power Factor, Phase B

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1162

True Power Factor, Phase C

0.001

-100 to 1,000 to 100

￿

 

 

 

 

 

 

1163

True Power Factor, Total

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

 

1164

Alternate True Power Factor, Phase A

0.001

0 to 2,000

 

 

 

 

 

 

 

 

 

1165

Alternate True Power Factor, Phase B

0.001

0 to 2,000

 

 

 

 

 

 

 

 

 

1166

Alternate True Power Factor, Phase C

0.001

0 to 2,000

￿

 

 

 

 

 

 

 

 

1167

Alternate True Power Factor, Total

0.001

0 to 2,000

 

 

 

 

 

 

 

 

1168

Displacement Power Factor, Phase A

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1169

Displacement Power Factor, Phase B

0.001

-100 to 1,000 to 100

 

 

 

 

 

 

 

1170

Displacement Power Factor, Phase C

0.001

-100 to 1,000 to 100

￿

 

 

 

 

 

 

1171

Displacement Power Factor, Total

0.001

-100 to 1,000 to 100 ￿

 

 

 

 

 

 

 

 

1172

Alternate Displacement Power Factor, Phase A

0.001

0 to 2,000

 

 

 

 

 

 

 

 

 

1173

Alternate Displacement Power Factor, Phase B

0.001

0 to 2,000

 

 

 

 

 

 

 

 

 

1174

Alternate Displacement Power Factor, Phase C

0.001

0 to 2,000

￿

 

 

 

 

 

 

 

 

1175

Alternate Displacement Power Factor, Total

0.001

0 to 2,000 ￿

 

 

 

 

 

 

 

 

1180

Frequency

0.01 Hertz

(50/60) 2,300 to 6,700

 

0.1 Hertz

(400) 3,500 to 4,500

 

 

 

 

 

 

 

 

 

 

 

1181

Temperature

0.1 °C

-1,000 to 1,000

 

 

 

 

 

 

 

 

1190

Auxiliary Analog Input Value, User-Selected Input 1

Refer to Analog Input

-32,767 to 32,767

 

Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1191

Auxiliary Analog Input Value, User-Selected Input 2

Refer to Analog Input

-32,767 to 32,767

 

Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1192

Auxiliary Analog Input Value, User-Selected Input 3

Refer to Analog Input

-32,767 to 32,767

 

Setup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See “How Power Factor is Stored in the Register” on page 128.

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.