Appendix A—Abbreviated Register Listing

63230-300-212

Register Listing

April 2001

 

 

Table A–3:Abbreviated Register List

Register

Description

Scale

Units

Register Range

 

Number

Factor

 

 

 

 

 

 

 

 

 

 

 

1504

Maximum Current, Ground

C

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1505

Maximum Current, 3 Phase Average

A

Amps/Scale

0 to 32,767 ￿

 

 

 

 

 

 

 

1506

Maximum Current, Apparent RMS

A

Amps/Scale

0 to 32,767

 

 

 

 

 

 

 

1507

Maximum Current Unbalance, Phase A

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1508

Maximum Current Unbalance, Phase B

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1509

Maximum Current Unbalance, Phase C

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1510

Maximum Current Unbalance, Max

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1520

Maximum Voltage, A-B

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1521

Maximum Voltage, B-C

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1522

Maximum Voltage, C-A

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1523

Maximum Voltage, L-L Average

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1524

Maximum Voltage, A-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1525

Maximum Voltage, B-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1526

Maximum Voltage, C-N

D

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1527

Maximum Voltage, N-G

E

Volts/Scale

0 to 32,767

 

 

 

 

 

 

 

1528

Maximum Voltage, L-N Average

D

Volts/Scale

0 to 32,767 ￿

 

 

 

 

 

 

 

1529

Maximum Voltage Unbalance, A-B

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1530

Maximum Voltage Unbalance, B-C

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1531

Maximum Voltage Unbalance, C-A

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1532

Maximum Voltage Unbalance, Max L-L

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1533

Maximum Voltage Unbalance, A-N

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1534

Maximum Voltage Unbalance, B-N

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1535

Maximum Voltage Unbalance, C-N

0.10%

-1,000 to 1,000

 

 

 

 

 

 

 

1536

Maximum Voltage Unbalance, Max L-N

0.10%

-1,000 to 1,000 ￿

 

 

 

 

 

 

 

1540

Maximum Real Power, Phase A

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1541

Maximum Real Power, Phase B

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1542

Maximum Real Power, Phase C

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1543

Maximum Real Power, Total

F

kW/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1544

Maximum Reactive Power, Phase A

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1545

Maximum Reactive Power, Phase B

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1546

Maximum Reactive Power, Phase C

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1547

Maximum Reactive Power, Total

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1548

Maximum Apparent Power, Phase A

F

kVA/Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1549

Maximum Apparent Power, Phase B

F

kVA /Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1550

Maximum Apparent Power, Phase C

F

kVA /Scale

-32,767 to 32,767

 

 

 

 

 

 

 

1551

Maximum Apparent Power, Total

F

kVA /Scale

-32,767 to 32,767

￿

See “How Power Factor is Stored in the Register” on page 128.

The alternate storage method for power factor (PF) is useful for outputting PF on analog outputs. The PF value is stored as a positive value between 0 and 2, centered around 1 (unity). A value of 0 lagging maps to 0; -0.999 maps to 0.999;0.999 leading maps to 1.001; and 0 leading maps to 2. The alternate PF is also stored with a scale factor 0.001.

These configuration registers require that you enter the setup mode to change the register’s contents. Issue command 9020 to enter setup mode and 9021 to exit setup mode. See “Using the Command Interface to Change Configuration Registers” on page 187 for instructions on

￿how to use the setup-mode commands.

Quantity available for 4-wire system only. Value set to -32,768 if not available.