63230-300-212 AppendixAAbbreviatedR egisterListing
April 2001 Registe r Listing
133
© 2001 Schneider Electric All Rights Reserved
1193 Auxiliary An alog Input Value, User-Selected Input 4 R efer to Analog Input
Setup -32,767 to 32,76 7
1194 Auxiliary An alog Input Value, User-Selected Input 5 R efer to Analog Input
Setup -32,767 to 32,76 7
1195 Auxiliary An alog Input Value, User-Selected Input 6 R efer to Analog Input
Setup -32,767 to 32,76 7
1196 Auxiliary An alog Input Value, User-Selected Input 7 R efer to Analog Input
Setup -32,767 to 32,76 7
1197 Auxiliary An alog Input Value, User-Selected Input 8 R efer to Analog Input
Setup -32,767 to 32,76 7
1198 Auxiliary An alog Input Value, User-Selected Input 9 R efer to Analog Input
Setup -32,767 to 32,76 7
1199 Auxiliary An alog Input Value, User-Selected Input 10 Refert o Analog Input
Setup -32,767 to 32,76 7
Power Quality
1200 THD/thd Cu rrent, Phase A 0.10% 0 to 32,767
1201 THD/thd Cu rrent, Phase B 0.10% 0 to 32,767
1202 THD/thd Cu rrent, Phase C 0.10% 0 to32,767
1203 THD/thd Cu rrent, Neutral 0.10% 0 to 32,767
1204 THD/thdCurrent, Ground 0.10% 0 to 32,767
1207 THD/thdVoltage, PhaseA-N 0.10% 0 to32,767
1208 THD/thdVoltage, PhaseB-N 0.10% 0 to32,767
1209 THD/thdVoltage, PhaseC-N 0.10% 0 to 32,767
1210 THD/thdVoltage, PhaseN-G 0.10% 0 to 32,767
1211 THD/thdVoltage, PhaseA-B 0.10% 0 to 32,767
1212 THD/thdVoltage, PhaseB-C 0.10% 0 to32,767
1213 THD/thdVoltage, PhaseC-A 0.10% 0 to32,767
1218 K-Factor, Current , Phase A 0.10 0to10,000
1219 K-Factor, Current , Phase B 0.10 0to10,000
1220 K-Factor, Current , Phase C 0.10 0to10,000
1221 Crest Factor, Cur rent, Phase A 0.01 0to10,000
1222 Crest Factor, Cur rent, Phase B 0.01 0to10,000
1223 Crest Factor, Cur rent, Phase C 0.01 0to10,000
1224 Crest Factor, Cur rent, Neutral 0.01 0to10,000
1225 Crest Factor, Voltage, A -N/A-B 0.01 0to10,000
1226 Crest Factor, Voltage, B -N/B-C 0.01 0to10,000
1227 Crest Factor, Voltage, C- N/C-A 0.01 0to10,000
1230 Current Fund amental RMS Magnitude, Pha se A A A mps/Scale 0 to 3 2,767
Tabl e A3:AbbreviatedRegister List
Register
Number Description Scale
Factor Units Regist er Range
See HowPower Factoris Stored in the Registeronpage 128.
Thealternate storage methodfor power factor(PF) is useful for outputtingPF on analog outputs.The PF value isstored as a positive value
between 0 and 2, centered around 1 (un ity). A value of 0 lagging maps to 0; -0.99 9m aps to 0.999;0.999 leading m aps to 1.001; and 0 leading
mapsto 2. The alternate PF is alsostored with a scale factor0.001.
These configuration r egisters require th at you enter the setup mo de to change the regi sters contents. Issue command 9020 t o enter setup
modeand 9021 to exit setup mode.S ee Usingthe Command Interfaceto Change ConfigurationRegistersonpage 187 for instructions on
howto use the setup-mode commands.
Quantity available for 4-w ire system only. Value set to -32, 768 if not available.