AC75 AT Command Set

4.8 AT+ILRR

s

4.8AT+ILRR Set TE-TA local rate reporting

The command AT+ILRR controls whether or not the intermediate result code "+ILRR" is transmitted from the TA to the TE while a connection is being set up. The result code indicates the local rate. It is issued before the final result code of the connection, e.g. CONNECT, is transmitted to the TE.

Syntax

Test Command

AT+ILRR=?

Response(s)

+ILRR: (list of supported <value>s)

OK

Read Command

AT+ILRR?

Response(s)

+ILRR: <value>

OK

Write Command

AT+ILRR=<value>

Response(s)

OK ERROR +CME ERROR

Reference(s)

V.250

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

+

+

-

-

+

-

-

-

+

-

Intermediate Result Code

+ILRR: <rate>

Indicates local port rate setting upon connection setup.

Parameter Description

<value>(num)(&W)(&V)

0(&F)

Disables reporting of local port rate

1

Enables reporting of local port rate

<rate>(num)

Port rate setting upon connection setup (bps)

0

Autobauding (see Section 4.9.1, Autobauding). Not supported on ASC1. Not

 

 

usable with Java.

 

 

300

 

 

 

600

 

 

 

1200

 

 

 

2400

 

 

 

4800

 

 

 

9600

 

 

 

 

 

 

 

 

AC75_ATC_V01.002

Page 114 of 569

10/30/06

Confidential / Released

 

 

 

Page 114
Image 114
Siemens AC75 manual AT+ILRR Set TE-TA local rate reporting, At+Ilrr=?, At+Ilrr?