AC75 AT Command Set

2.14 AT^SCFG

s

<udbgif2>(str)(+CSCS)

Userware Debug Interface Remote IP address

IP address of the host running the userware debugger.

Parameter is global, volatile and not reset by AT&F.

<udbgif3>(str)(+CSCS)

Default interface flag for IP connections

Flag to select if the userware debug interface is the default interface for IP connections. Parameter is global, volatile and not reset by AT&F.

[“0“]

Debug interface is not the default.

“1“

Debug interface is default for IP connections.

 

 

<umode>(str)(+CSCS)

 

Userware Mode

 

Parameter is global, volatile and not reset by AT&F.

[“normal“]

Userware is started by AT command or autostart option.

“debug“

Userware is started by debugger on host side.

“test“

Userware is loaded from test server.

 

 

<uurl>(str)(+CSCS)

 

Userware Mode: Location

 

Use of parameter depends on selected userware mode. Parameter is global, volatile and not reset by AT&F.

If <umode>= "normal": Parameter is ignored.

If <umode>= "debug": File name of application stored on module. Maximum length: 126 characters.

If <umode>= "test": URL of the test server. Maximum length: 126 characters.

<uport>(str)(+CSCS)

Userware Mode: Port

Use of parameter depends on selected userware mode.

Parameter is global, volatile and not reset by AT&F.

0...65535

If <umode>= "normal": Parameter is ignored.

 

If <umode>= "debug": Port number used by debugger.

 

If <umode>= "test": Port number of the test server.

 

 

<if>(str)(+CSCS)

 

Interface for Java System.out

 

This parameter specifies the interface to be used for the Java standard output System.out. The selected inter- face must be supported by the hardware.

 

“ASC0“

System.out is routed to the first serial interface.

 

 

 

 

The interface is shared between Java CommConnection and System.out. The

 

 

baud rate set for CommConnection applies also to System.out.

 

 

 

 

The value is global, stored non-volatile in ME and is not reset by AT&F.

 

“ASC1“(D)

System.out is routed to the second serial interface.

 

 

 

 

The interface is shared between Java CommConnection and System.out. The

 

 

baud rate set for CommConnection applies also to System.out.

 

 

 

 

The value is global, stored non-volatile in ME and is not reset by AT&F.

 

“USB“

System.out is routed to the Universal Serial Bus interface.

 

 

 

 

 

 

 

AC75_ATC_V01.002

Page 75 of 569

10/30/06

Confidential / Released

 

 

 

Page 75
Image 75