AC75 AT Command Set

2.14 AT^SCFG

s

<urat>(str)(+CSCS)

URC RING line Active Time

This parameter can be used to control how long the RING line is activated to indicate URCs (both for idle inter- faces and, if configured by the parameter "URC/Datamode/Ringline" (<udri>), if link is reserved) and, if con- figured by the parameter "GPRS/RingOnIncomingData", to indicate incoming GPRS IP data packets

(<groid>).

Parameter is global for all interfaces, volatile and will not be reset by AT&F.

“0“

RING line will be activated for a time between 4.6 and 9.2 ms.

“1“

RING line will be activated for about 100ms.

“2“(P)

RING line will be activated for about 1s.

 

 

<ua>(str)(+CSCS)

 

Userware Autostart

 

Specifies if the userware is started automatically on power-up.

If autostart is enabled, it is no longer possible to use the multiplexer (see AT+CMUX). If the Java application starts, all current calls will be terminated.

The Userware/Autostart mechanism takes effect also in Airplane modeand CHARGE-ONLY-MODE. Parameter is global, stored non-volatile in ME and not reset by AT&F.

“0“(D)

Userware autostart disabled

“1“

Userware autostart enabled

 

 

<uaa>(str)(+CSCS)

 

Userware Autostart AppName

 

Specifies the absolute path of the userware (the jar/jad file containing the desired application) to be started auto- matically on power-up. The local flash file system is identified by: "A:", directory separator is "/" (002Fh). The underline character "_" (005Fh) will not be supported.

Parameter is global, stored non-volatile in ME and not reset by AT&F. Parameter length: maximum 100 characters.

<uad>(str)(+CSCS)

Userware Autostart Delay

 

0(D)...10000

Specifies the delay time (in 100ms) when the userware is started automatically

 

after power-up.

 

Parameter is global, stored non-volatile in ME and not reset by AT&F.

 

 

<upwd>(str)(+CSCS)

 

Userware Password

 

Password used to change values of userware parameters. Parameter is global, stored non-volatile in ME and not reset by AT&F.

The maximum length of a given password is 8 characters. It is allowed to have an empty password (this is the value on delivery of the module).

CAUTION: Be careful not to lose the password. There is no way to reset or recover a forgotten password or to obtain a new password from the manufacturer.

<udbgif1>(str)(+CSCS)

Userware Debug Interface Local IP address

Local IP address of the module used by the userware debugger.

Parameter is global, volatile and not reset by AT&F.

AC75_ATC_V01.002

Page 74 of 569

10/30/06

Confidential / Released

 

 

Page 74