AC75 AT Command Set

8.5 AT+CSQ

s

8.5AT+CSQ Signal quality

The AT+CSQ execute command indicates the received signal strength <rssi> and the channel bit error rate <ber>.

Syntax

Test Command

AT+CSQ=?

Response(s)

+CSQ: (list of supported<rssi>s), (list of supported<ber>s)

OK

Exec Command

AT+CSQ

Response(s)

+CSQ: <rssi>,<ber>

OK

Reference(s)

GSM 07.07

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

+

+

+

+

-

-

-

Parameter Description

<rssi>(num)

0

-113 dBm or less

1

-111 dBm

2..30

-109... -53 dBm

31

-51 dBm or greater

99

not known or not detectable

 

 

<ber>(num)

 

0..7

as RXQUAL values in the table in GSM 05.08 section 8.2.4.

99

not known or not detectable

Note

After using network related commands such as AT+CCWA, AT+CCFC, AT+CLCK, users are advised to wait 3s before entering AT+CSQ. This is recommended to be sure that any network access required for the preceding command has finished.