AC75 AT Command Set

3.4 AT+CEER

s

3.4AT+CEER Extended Error Report

AT+CEER returns an extended error report regarding the reason of the last

call release

failure to set up a call (both mobile originated or terminated)

failure to modify a call by using Supplementary Services

failed attempt to activate, register, query, deactivate or deregister a Supplementary Service

unsuccessful GPRS attach or unsuccessful PDP context activation

GPRS detach or PDP context deactivation

The release cause report is presented in numeric format. Default output in case of a none-error-situation is +CEER: 0,0,0. A description associated with each number can be found in the tables given in the following sub- clauses and the relevant GSM specifications.

The first parameter <locationID> serves to locate the other two parameters. Depending on the failure or release cause either <reason> or <ssRelease> are applicable, i.e. if <reason> 0, then <ssRelease> = 0. Vice versa, if <reason> = 0, then <ssRelease> may be 0.

In addition to AT+CEER, the command ATS18 can be used to check especially the status of fax and data calls.

Syntax

Test Command

AT+CEER=?

Response(s)

OK ERROR +CME ERROR

Exec Command

AT+CEER

Response(s)

+CEER: <locationID>, <reason>, <ssRelease>

OK ERROR +CME ERROR

Reference(s)

GSM 07.07

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

+

+

+

+

+

+

+

-

+

-

Parameter Description

<locationID>(num)

Location ID as number code. Location IDs are listed in Section 3.4.1, Cause Location ID for the extended error report. Each ID is related with another table that contains a list of <reason>s or <ssRelease>s.

<reason>(num)

Reason for last call release as number code. The number codes are listed in several tables, sorted by different categories in the following subclauses. The tables can be found proceeding from the Location ID given in Sec- tion 3.4.1, Cause Location ID for the extended error report.

<ssRelease>(num)

Release cause for last Supplementary Service call (listed in Section 3.4.9, GSM Release cause for Supplemen- tary Service Call)

AC75_ATC_V01.002

Page 92 of 569

10/30/06

Confidential / Released

 

 

Page 92
Image 92
Siemens AC75 manual AT+CEER Extended Error Report, At+Ceer=?, +CEER locationID, reason, ssRelease