AC75 AT Command Set

10.3 AT^SISS

s

-Socket type UDP client URL

"sockudp://'host':'remote udpPort'[;size='byte'][;port='word']" Parameter "size" (optional):

0: PDU size is variable (default).

1 ... 1500: Fixed PDU size in bytes. Parameter "port" (optional):

0: Port number will be assigned from service (default).

1 ... 216-1: defines the local port number for the UDP client.

2.FTP

-FTP client URL (get) "ftp://'user':'password'@'host':'tcpPort'/'url-path' [;type='aid'] " Refer to "IETF-RFC 1738".

-FTP client URL (put)

"ftpput://'user':'password'@'host':'tcpPort'/'url-path'/'element name' [;type='ai'][;mode='uad'] "

Used parameters:

"host" is mandatory, all other parameters are optional. If "password" is set then "user" must be set as well.

If "user" is omitted the string "anonymous" is selected for "user" and "pass- word".

If "password" is omitted the password request is served by an empty string. If "tcpPort" is omitted the service connects to the FTP default port 21.

If "url-path" contains only the IP address a directory listing is requested.

If "url-path" contains the IP address and has a slash '/' appended a detailed directory listing is requested.

"type": [a)scii i)mage d)irectory]

"mode": [u)nique a)ppend d)elete]

"u)nique" selects the FTP Store Unique command to create a file name unique to the current directory. If the file name is assigned by the server then the "^SIS" URC will appear, indicating <urcInfoId> 2100 and the file name.

"d)elete" clears given 'element name'.

If "mode" is omitted "replace mode" is default setting.

3. HTTP

 

 

HTTP client URL

 

 

 

Length: 6 ... 255

 

 

 

"http://'server'/'path':'tcpPort' "

 

 

 

"server": FQDN or IP-address

 

 

 

"path": path of file or directory

 

 

 

"tcpPort": If parameter is omitted the service connects to HTTP default port

 

 

80.

 

 

 

Refer to "IETF-RFC 2616".

 

 

 

4. SMTP SMTP server address (string).

 

 

 

Length: 4 ... 256.

 

 

 

5. POP3 POP3 server address (string).

 

 

 

Length: 4 ... 256.

 

 

hcContent

Optional parameter for HTTP method "Post".

 

 

 

Length: 0 ... 127

 

 

 

Can be used to transfer a small amount of data. The content of this string will

 

 

only be sent if "hcContLen" = 0. The maximum length of "hcContent" is 127

 

 

bytes.

 

 

 

To transmit a larger amount of data "hcContLen" must be set to a non-zero

 

 

value. In this case the "hcContent" string will be ignored, and data transmission

 

 

from the client to the server is done with AT^SISW.

 

 

hcContLen

Mandatory parameter for HTTP method "Post".

 

 

 

Length: 0 ... 231-1

 

 

 

The content length shall be set in the header of the HTTP "Post" request before

 

 

the data part is transferred.

 

 

 

If "hcContLen" = 0 then the data given in the "hcContent" string will be posted.

 

 

 

 