8.8AT^SFNUR Select the fixed network user rate

The AT^SFNUR command specifies the Fixed Network User Rate (FNUR) parameter. This parameter is impor- tant only for mobile originated 14.4 kbit/s UDI calls (AT+CBST=75) and mobile terminated data calls if the bearer capability information element is delivered without data bearer service (see AT+CSNS and AT+CBST commands).

Changes are recommended only if a CSD call fails. The choice as to which of the values to use depends on the GSM network and the location. Users should be aware that even the same operator may apply varying FNUR configurations in different regions.

The AT^SFNUR command has no effect on CSD connections controlled by the Internet Service commands. If needed for the Internet Services the Fixed Network User Rate can be set in the connection profile. For details see AT^SICS, parameter <conParmValue> "fnur".

Syntax

Test Command

AT^SFNUR=?

Response(s)

^SFNUR:(list of supported <value>s)

OK

Read Command

AT^SFNUR?

Response(s)

^SFNUR: <value>

OK ERROR

+CME ERROR: <err>

Write Command

AT^SFNUR=<value>

Response(s)

OK ERROR

+CME ERROR: <err>

Reference(s)

SIEMENS

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

+

+

+

+

-

+

-

Parameter Description

<value>(num)

0

not applicable

 

1

9.6 kbit/s

 

 

2(P)

14.4 kbit/s

 

3

19.2 kbit/s

 

4

28.8 kbit/s

 

5

38.4 kbit/s

 

6

48.0 kbit/s

 

7

56.7 kbit/s

 

8

64.0 kbit/s

 

 

 

 

 

AC75_ATC_V01.002

Page 209 of 569

10/30/06

Confidential / Released

 

 

Page 209
Image 209