AC75 AT Command Set

19.7 AT^SSYNC

s

19.7.1ME status indicated by status LED patterns

The following table lists the possible patterns of status LED behavior, and describes the ME operating status indi- cated by each pattern if AT^SSYNC parameter <mode>=1 and <mode>=2. To better monitor the operating states while power saving is enabled, we recommend that priority be given to <mode>=2.

During the transition from one LED pattern to another the "on" and/or "off" periods of the LED may vary in length. This is because an event that triggers the change may occur any time and, thus, truncate the current LED pattern at any point.

The statements on LED behavior during SLEEP mode are not applicable if the USB cable is plugged. This is because power saving with connected USB host does not take effect if set with AT+CFUN only. For details see notes provided with AT+CFUN. Therefore, while the USB cable is plugged, the LED is always on and flashes as if the module works at AT+CFUN=1, no matter whether AT^SSYNC=1 or AT^SSYNC=2 is enabled.

Table 19.1: Modes of the LED and indicated ME functions

LED behavior

ME operating status if AT^SSYNC=1

ME operating status if AT^SSYNC=2

Permanently off

ME is in one of the following modes:

ME is in one of the following modes:

 

- POWER DOWN mode

- POWER DOWN mode

 

- AIRPLANE mode

- AIRPLANE mode

 

- CHARGE ONLY mode

- CHARGE ONLY mode

 

- NON-CYCLIC SLEEP mode

 

 

- CYCLIC SLEEP mode with no tempo-

 

 

rary wake-up event in progress 1)

 

600 ms on / 600ms off

Limited Network Service: No SIM card

Same as for AT^SSYNC=1

 

inserted or no PIN entered, or network

 

 

search in progress, or ongoing user

 

 

authentication, or network login in

 

 

progress.

 

75 ms on / 3 s off

IDLE mode: The mobile is registered to

Same as for AT^SSYNC=1

 

the GSM network (monitoring control

 

 

channels and user interactions). No call

 

 

is in progress.

 

75 ms on / 75 ms off /

One or more GPRS PDP contexts acti-

Same as for AT^SSYNC=1

75 ms on / 3 s off

vated.

 

500 ms on / 50 ms off

Packet switched data transfer is in

Same as for AT^SSYNC=1

 

progress.

 

Permanently on

Depending on type of call:

Same as for AT^SSYNC=1

 

Voice call: Connected to remote party.

 

 

Data call: Connected to remote party or

 

 

exchange of parameters while setting

 

 

up or disconnecting a call.

 

<n> ms on / <n> ms off 2)

Not possible: With AT^SSYNC=1, LED

SLEEP mode is activated (AT+CFUN

 

signalization is disabled in SLEEP

parameter <fun> 1), but the ME is not

 

mode.

registered to the GSM network (e.g. SIM

 

 

not inserted or PIN not entered, and

 

 

therefore, either no network service or

 

 

only Limited Network Service is avail-

 

 

able.

 

 

 

AC75_ATC_V01.002

Page 494 of 569

10/30/06

Confidential / Released

 

 

Page 494
Image 494
Siemens AC75 manual ME status indicated by status LED patterns