AC75 AT Command Set

4.11 AT^STPB

s

4.11

AT^STPB Transmit Parity Bit (for 7E1 and 7O1 only)

This command is intended only for use with 7E1 and 7O1. In addition to the 7E1 or 7O1 settings made with AT+ICF the command AT^STPB specifies whether or not to transmit the parity bit over the air.

Syntax

Test Command

AT^STPB=?

Response(s)

^STPB: (list of supported <n>s)

OK

Read Command

AT^STPB?

Response(s)

^STPB: <n>

OK

Write Command

AT^STPB=<n>

Response(s)

OK ERROR

+CME ERROR: unknown

Reference(s)

SIEMENS

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

-

±

±

±

-

+

-

Command Description

The test command returns the supported values of the parameter <n>. The read command returns the current value of the parameter <n>.

The write command can be used to control the handling of the parity bit. If command fails, "+CME ERROR: unknown" will be returned.

Parameter Description

<n>(num)(&W)

0(&F)

The parity bit will not be transmitted over the air and will be replaced with 0.

 

This mode is the default setting if 7E1 or 7O1 is activated with AT+ICF.

1

In a data connection 8 bits will be transmitted, including the parity bit, i.e. the

 

parity bit will be properly transmitted over the air. The setting shall be used if

 

problems are encountered when AC75 is running in the default 7E1 or 7O1

 

mode enabled with AT+ICF. In this case, AT^STPB=1 shall be set in addition

 

to the 7E1 or 7O1 settings selected with AT+ICF.

Note

Command is usable if multiplexer is enabled but setting is ignored.

AC75_ATC_V01.002

Page 123 of 569

10/30/06

Confidential / Released

 

 

Page 123
Image 123
Siemens AC75 manual Atstpb=?, Atstpb?, Stpb n, ATSTPB=n, +CME Error unknown