AC75 AT Command Set

7.4 ATD><mem><n>

s

Notes

This command may be aborted generally by receiving a character during execution. Abortion is not possible during some states of connection setup such as handshaking.

There is no <mem> for emergency call ("EN").

The command is not applicable to data calls. Any attempt to dial a data call number from <mem> causes the result code "NO CARRIER" to appear.

Parameter <mgsm> only if no *# code is within the dialing string.

See ATX for setting result code and call monitoring parameters.

Any string after <mgsm> and before ';' are ignored.

Examples

EXAMPLE 1

To query the location number of the phonebook entry:

AT+CPBR=1,xx

TA returns the entries available in the active phonebook.

EXAMPLE 2

To dial a number from the SIM phonebook, for example the number stored to location 15:

ATD>SM15;

OK

EXAMPLE 3

To dial a phone number stored in the last dial memory on the SIM card:

ATD>LD9;

OK

AC75_ATC_V01.002

Page 161 of 569

10/30/06

Confidential / Released

 

 