Siemens AC75 manual Mgsmstr, ATD03022222222

Models: AC75

1 569
Download 569 pages 6.58 Kb
Page 159
Image 159

AC75 AT Command Set

7.3 ATD

s

<mgsm>(str)

String of GSM modifiers:

I Activates CLIR (disables presentation of own phone number to called party)

iDeactivates CLIR (enables presentation of own phone number to called party) G Activate Closed User Group explicit invocation for this call only.

g Deactivate Closed User Group explicit invocation for this call only.

Notes

The command may be aborted generally when receiving a character during execution. It cannot be aborted in some connection setup states, such as handshaking.

Parameter "I" and "i" only if no *#-code is within the dial string.

<mgsm> is not supported for data calls.

<n> is default for last number that can be dialled by ATDL.

See also ATX for <text>.

If ATD is used with a USSD command (e.g. ATD*100#;) an AT+CUSD=1 is executed implicitly (see AT+CUSD).

Parameter 'G' or 'g' will be ignored if Closed User Group was already activated, respectively deactivated with AT+CCUG command before. Call by call invocation of CUG uses the settings provisioned by the provider or, if available, the settings of the parameters <index> and <info> made with AT+CCUG.

The ME is equipped with a "Blacklist" function according to GSM02.07 Annex A:

After a predefined number of failed call attempts, the dialed number is entered into a read-only phonebook called "blacklist" (phonebook "BL"). Call attempts to numbers contained in the blacklist will be barred by ME and not signalled to the network.

An attempt to start a voice call to a barred phone number will be stopped with a CME ERROR 257 "Call Barred".

An attempt to start a data or fax call to a barred phone number will be answered immediately with result code "NO CARRIER".

The barred numbers are automatically removed from the blacklist according to the timing conditions specified in GSM02.07 Annex A.

Emergency calls: AC75 supports 112, 911 (standardized GSM emergency numbers, usable with or without SIM).

If a SIM with ECC-file is inserted, additional call numbers stored in the ECC-file cause an emergency call setup.

If SIM without ECC-file is inserted, call numbers 000, 08, 110, 112, 911 and 999 cause an emergency call setup.

If no SIM is inserted, call numbers 000, 08, 110, 112, 118,119, 911 and 999 cause an emergency call setup.

To start ATD via AC75's DTR line AT^SCFG may be used, refer parameter <AutoExecATC>.

Example

The following example shows the call setup procedure when a call is already active and a second call attempt fails because the line of the called party is busy:

atd03012345678

Dialing out the first party's number.

OK

The first call is established.

ATD03022222222

The number of the second party is dialed.

OK

The response "OK" is issued immediately though no call is established

 

(same behavior as is you had chosen AT^SM20=0.)

BUSY

Line of the second called party is busy.

 

 

AC75_ATC_V01.002

Page 159 of 569

10/30/06

Confidential / Released

 

 

Page 159
Image 159