AC75 AT Command Set

12.2 AT+FCLASS

s

12.2 AT+FCLASS Fax: Select, read or test service class

AT+FCLASS sets the ME to a particular mode of operation (data, fax). This allows the ME to process information in a manner suitable for that type of information.

Syntax

Test Command

AT+FCLASS=?

Response(s)

(list of supported <n>s)

OK

Read Command

AT+FCLASS?

Response(s)

<n>

OK

Write Command

AT+FCLASS=<n>

Response(s)

OK

Reference(s)

EIA/TIA-592-A

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

-

+

+

-

-

-

+

-

Parameter Description

<n>(num)(&W)(&V)

0(&F)

Data (e.g. EIA/TIA-602 or ITU V.250)

1

Fax class 1 (EIA/TIA-578-A, Service Class 1)

Notes

Using Error Correcting Mode (ECM) when sending FAXes over GSM should be avoided.

If <n> is set to 1, all incoming calls will be answered as fax calls when ATA is issued on multiplexer channel 1 resp. ASC0. For calls explicitly signaled as voice or data calls, this procedure will fail with result code "NO CARRIER", but the incoming call will continue to ring.

It is possible to change the setting of <n> to 0 while the call is ringing, and accept the call afterwards with ATA.

AC75_ATC_V01.002

Page 353 of 569

10/30/06

Confidential / Released

 

 

Page 353
Image 353