AC75 AT Command Set

8.7 AT^SMOND

s

<BER>(num)

Bit Error rate, with value 99 indicating "not known or not detectable"

0...7

as RXQUAL values RXQUAL0 to RXQUAL7 in GSM 05.08 section 8.2.4

Notes

To some extent, the cell monitoring commands AT^SMOND, AT^MONI, AT^MONP and AT^SMONC cover the same parameters. The receiving level, for example, can be queried with all three commands. Yet the resulting values may be slightly different, even though obtained over a time period of a few seconds. This is quite nor- mal and nothing to worry about, as the cell information is permanently updated.

During a connection, not all of the neighbour cell information can be decoded. The following restrictions apply:

-Information is updated only for neighbour cells that have already been visible at connection setup, and continue to be included in the list of cells.

-New neighbour cells added to the list, for example after handover, cannot be displayed until the connection is released.

Example

at^smond

Execute command

^SMOND:262,01,3008,6060,32,100,66,,,0,,,0,

Line breaks inserted for readability in print

262,01,3008,DDD1,35,92,80,

262,01,3008,,31,96,83,

262,01,3008,BFBE,35,27,86,

262,01,3008,,32,98,88,

262,01,3008,BB44,32,90,89,

262,01,3008,8307,31,22,93,

2,23,99

AC75_ATC_V01.002

Page 208 of 569

10/30/06

Confidential / Released

 

 

Page 208
Image 208
Siemens AC75 manual Atsmond, SMOND262,01,3008,6060,32,100,66,,,0,,,0