AC75 AT Command Set
13.28 AT^SSMSS s
AC75_ATC_V01.002 Page 401 of 569 10/30/06
Confidential / Released
13.28 AT^SSMSS Set Short Message Storage Sequence
The short message storage ''MT'' (see AT+CPMS) is a logical storage. It consists of two physical storages ''ME''
and ''SM''. This command allows to select the sequence of addressing this storage.
Syntax
Parameter Description
MT sequence
0(&F) ''MT'' storage is ''ME'' then ''SM
1 ''MT'' storage is ''SM'' then ''ME''
Note
•The <seq> parameter will be stored in non-volatile memory.
Test Command
AT^SSMSS=?
Response(s)
^SSMSS: (list of supported) <seq>s
Read Command
AT^SSMSS?
Response(s)
^SSMSS: <seq>
OK
Write Command
AT^SSMSS=<seq>
Response(s)
OK
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4Last
SIEMENS + + + + + + + - + -
<seq>(num)