AC75 AT Command Set

20.7 AT^SSIO

s

20.7

AT^SSIO Set IO state of a specified pin or port

Syntax

Test Command

AT^SSIO=?

Response(s)

^SSIO:(list of supported <io_id>s), (list of supported <value>s)

OK

Write Command

AT^SSIO=<io_id>, <value>

Response(s)

OK ERROR

+CME ERROR: <err>

Reference(s)

SIEMENS

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

+

+

+

+

-

+

-

Parameter Description

<io_id>(num)

This can be either an already configured <pin_id> or an already opened <port_id>.

<value>(num)

State to be set for this <io_id>.

0

Low for <pin_id>

1

High for <pin_id>

0...1023

For <port_id>

Notes

If you set a state on a port whose width is less than 10 bits, the bits of <value> that are more significant than the MSB of the port are ignored.

The write command is only applicable to <pin_id>s or <port_id>s which are configured as output.

AC75_ATC_V01.002

Page 516 of 569

10/30/06

Confidential / Released

 

 

Page 516
Image 516
Siemens AC75 manual Atssio=?, ATSSIO=ioid, value