4.6 AT+ICF

s

4.6AT+ICF Serial Interface Character Framing

The command AT+ICF controls the serial interface character framing format and parity used for receiving and transmitting.

The following settings are supported:

7 bits, even parity, 1 stop bit (AT+ICF=5,1)

7 bits, odd parity, 1 stop bit (AT+ICF=5,0)

8 bits, even parity, 1 stop bit (AT+ICF=2,1)

8 bits, no parity, 1 stop bit (AT+ICF=3)

8 bits, odd parity, 1 stop bit (AT+ICF=2,0)

8 bits, no parity, 2 stop bits (AT+ICF=1)

Syntax

Test Command

AT+ICF=?

Response(s)

+ICF: (list of supported <format>s), (list of supported <parity>s)

OK

Read Command

AT+ICF?

Response(s)

+ICF: <format>[, <parity>]

OK

Write Command

AT+ICF=[<format>[, <parity>]]

Response(s)

OK

ERROR

Reference(s)

V.250

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

-

±

±

±

-

+

-

Parameter Description

<format>(num)(&W)(&V)

Specifies the character format used for receiving and transmitting.

1

8 data 0 parity 2 stop

2

8 data 1 parity 1 stop

[3](D)

8 data 0 parity 1 stop

5

7 data 1 parity 1 stop

<parity>(num)(&W)(&V)

Specifies the method of calculating the parity bit, if a parity bit is supported by <format>. If <format> does not support parity, this parameter has to be omitted.

0

odd

1

even