AC75 AT Command Set

10.11 AT^SISX

s

10.11AT^SISX Internet Service Execution

The AT^SISX command sends ICMP (Internet Control Message Protocol) Echo Requests to a target IP address or host name (also referred to as Ping command).

The AT^SISX command can be used any time while a connection profile, i.e. a bearer, is active. The bearer may have been started either with AT^SICO, or if a service is in use, with AT^SISO. If issued although no bearer is active or no connection profile created at all, AT^SISX returns ERROR.

The AT^SISX write command starts the available service type <service>, i.e. the ping command. The com- mand returns one row for every ICMP Echo Request (max. 30 lines, see parameter <request>). The last Ping response line is followed by an empty line, then another two lines appear to report a statistic calculated from the Echo Request responses. To stop the periodic ping type any character, e.g. "AT" or "at". After calling the ping command the AT channel is blocked until all ICMP requests are executed.

Sending the Ping command does not restart the inactivity timeout "inactTO" of the used connection profile (see AT^SICS), i.e. if the bearer was opened with AT^SICO the "inactTO" value remains "-1" (= inactivity timeout dis- abled), and if the bearer was opened with AT^SISO the "inactTO" value set with AT^SICS remains applicable. The Ping command can only be used to prevent that a network initiated inactivity timeout closes the bearer (see also description of AT^SICO).

Syntax

Test Command

AT^SISX=?

Response(s)

^SISX:<service>, (list of supported <conProfileId>s), <address>, (range of <request>), (range of <timelimit>)

OK

Write Command

AT^SISX=<service>, <conProfileId>, <address>[, <request>, <timelimit>]

Response(s)

In case of <pingInfoType>= 1: ICMP Echo Requests (1 - 30 rows)

^SISX:<service>, <pingInfoType>, <conProfileId>, <address>, <roundTripTime>

[...]

In case of <pingInfoType>= 2: Packet statistic (1 row)

^SISX:<service>, <pingInfoType>, <conProfileId>, <sent>, <received>, <lost>, <lostPercent>

In case of <pingInfoType>= 3: Time statistic (1 row)

^SISX:<service>, <pingInfoType>, <conProfileId>, <minRTT>, <maxRTT>, <meanRTT>

OK ERROR

+CME ERROR: <err>

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

+

+

+

+

+

+

+

-

-

-

AC75_ATC_V01.002

Page 290 of 569

10/30/06

Confidential / Released

 

 

Page 290
Image 290
Siemens AC75 manual Atsisx Internet Service Execution, Atsisx=?, ATSISX=service, conProfileId, address, request, timelimit