AC75 AT Command Set

7.25 AT+CSNS

s

7.25AT+CSNS Single Numbering Scheme

The AT+CSNS command enables the ME to accept incoming calls when no bearer capability information is pro- vided with the call, e.g. single numbering scheme calls or calls originating from analog devices.

Syntax

Test Command

AT+CSNS=?

Response(s)

+CSNS: (list of supported<mode>s)

OK

Read Command

AT+CSNS?

Response(s)

+CSNS: <mode>

OK

Write Command

AT+CSNS=[<mode>]

Response(s)

OK ERROR +CME ERROR

Reference(s)

GSM 07.07

PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4 Last

-

+

+

+

+

+

+

-

+

-

Parameter Description

<mode>(num)

Parameter is non-volatile.

 

[0](D)

Voice: Each call received without bearer element is assumed to be speech

2

Fax: Each call received without bearer element is assumed to be an incoming

 

fax.

4

Data: Each call received without bearer element is assumed to be a data call.

 

Please take into account that the bearer service parameters set with AT+CBST

 

apply to all data calls including those received without bearer capability.

Notes

The command must be set before the call comes. By default, when you do not modify the settings, all calls received without bearer element are assumed to be voice.

If problems are encountered with CSD connections at 14.4 kbit/s you may be required to change the Fixed Network User Rate depending on the network. See AT^SFNUR for details.

AC75_ATC_V01.002

Page 189 of 569

10/30/06

Confidential / Released

 

 

Page 189
Image 189
Siemens AC75 manual 25 AT+CSNS Single Numbering Scheme, At+Csns=?, At+Csns?, +CSNS mode, AT+CSNS=mode