AC75 AT Command Set
7.25 AT+CSNS s
AC75_ATC_V01.002 Page 189 of 569 10/30/06
Confidential / Released
7.25 AT+CSNS Single Numbering SchemeThe AT+CSNS command enables the ME to accept incoming calls when no bearer capability information is pro-
vided with the call, e.g. single numbering scheme calls or calls originating from analog devices.
Syntax
Parameter Description
Parameter is non-volatile.
[0](D) Voice: Each call received without bearer element is assumed to be speech
2 Fax: Each call received without bearer element is assumed to be an incoming
fax.
4 Data: Each call received without bearer element is assumed to be a data call.
Please take into account that the bearer service parameters set with AT+CBST
apply to all data calls including those received without bearer capability.
Notes
• The command must be set before the call comes. By default, when you do not modify the settings, all calls
received without bearer element are assumed to be voice.
• If problems are encountered with CSD connections at 14.4 kbit/s you may be required to change the Fixed
Network User Rate depending on the network. See AT^SFNUR for details.
Test Command
AT+CSNS=?
Response(s)
+CSNS: (list of supported<mode>s)
OK
Read Command
AT+CSNS?
Response(s)
+CSNS: <mode>
OK
Write Command
AT+CSNS=[<mode>]
Response(s)
OK
ERROR
+CME ERROR
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4Last
GSM 07.07 - + + + + + + - + -
<mode>(num)