AC75 AT Command Set

2.14 AT^SCFG

s

Bit

Maskhex

Maskdec

Control

D0

0x00

0

00: Ignore ongoing calls

D1

0x01

1

01: Wait until all calls have ended

 

0x02

2

10: Dismiss any ongoing call

 

0x03

3

11: RFU

D2

0x04

4

0: One shot action

 

 

 

1: Periodic action (for "AutoExec/Period" only)

D3

0x08

8

RFU

D4

0x10

16

RFU

D5

0x20

32

RFU

D6

0x40

64

RFU

D7

0x80

128

RFU

<AutoExecATC>(str)(+CSCS)

AutoExec AT command String

This parameter specifies the AT command(s) to be launched automatically. Each AT command is executed in the same way as if it were entered online, this means that command concatenation is possible if supported by the given commands. If serial multiplex mode is activated (AT+CMUX) the first logical channel is used, i.e. CSD calls (data or fax) could be set up. If the AC75 is busy on the serial channel command execution will be delayed until ongoing action is finished.

The first two characters of the automatically launched AT command shall be "at". Please refer to examples below.

Value will be saved while switching off the AC75 via AT commands (e.g. AT+CFUN or AT^SMSO) and restored on next power up.

<AutoExecPeriod>(str)(+CSCS)

AutoExec Command Period

Parameter specifies the period after which <AutoExecATC> will be executed. Format is "hhh:mm:ss", where characters indicate hours, minutes and seconds. This parameter applies to <AutoExecType>=1 only.

Value will be saved while switching off the AC75 via AT commands (e.g. AT+CFUN or AT^SMSO) and restored on next power up.

When using this feature with running java applications, please consider the minimum time for the execution of AT+CFUN or AT^SMSO is 15 seconds.

000:00:05...240:00:00

<AutoExecPeriodTimeLeft>(str)(+CSCS)

AutoExec Command Period Left

This parameter shows the amount of time left until <AutoExecATC> will be executed. Format is "hhh:mm:ss", where characters indicate hours, minutes and seconds. This parameter applies to <AutoExecType>=1 only. Due to the internal activity and network signaling an execution delay of several seconds may occur for the overall procedure.

000:00:00...240:00:00

<AutoExecState>(str)(+CSCS)

AutoExec Command Status

This parameter is part of the Autoexec URC which is presented when a scheduled Autoexec activity is being performed.

“1“

The value 1 indicates that the Autoexec activity specified with <AutoExec-

 

ATC> is currently executed.

AC75_ATC_V01.002

Page 64 of 569

10/30/06

Confidential / Released

 

 

Page 64
Image 64
Siemens AC75 manual Rfu, AutoExecATCstr+CSCS, AutoExecPeriodstr+CSCS, AutoExecPeriodTimeLeftstr+CSCS, AutoExecStatestr+CSCS