AC75 AT Command Set

9.7 AT+CCWA

s

Parameter Description

<n>(num)

Switch URCs "+CCWA" and "^SCWA" for call waiting on/off

0

Disable display of URCs "+CCWA" and "^SCWA"

1

Enable display of URCs "+CCWA" and "^SCWA"

<mode>(num)

Network operation to be performed for Supplementary service call waiting

0

Disable call waiting (disable service)

1

Enable call waiting (enable service)

2

Query status of call waiting (query service status)

<class>(num)

Integer or sum of integers each representing a class of information, i.e. a bearer service, telecommunication ser- vice or bearer service group as defined in "GSM 02.04".

In the write command, parameter <class> specifies the class of the active call during which an incoming call of any class is to be regarded as a waiting call.

In URC "+CCWA: <calling number>, <type of number>, <class>, , <CLI validity>", parameter <class> specifies the class of the waiting call.

1

Voice

2

Data

 

<class> 2 (data) comprises all those <class> values between 16 and 128, that

 

are supported both by the network and the MS. This means, a setting made for

 

<class> 2 applies to all remaining data classes (if supported). In addition, you

 

can assign a different setting to a specific class. For example, you can activate

 

call waiting for all data classes, but deactivate it for a specific data class.

4

Fax

[7]

Voice, data and fax (1+2+4)

16

Data circuit sync

32

Data circuit async

64

Dedicated packet access

128

Dedicated PAD access

1...[7]...255

Combination of some of the above classes. For example, the default setting 7

 

represents the sum of the integers 1, 2 and 4 (CF for voice, data and fax). The

 

value 255 covers all classes. If parameter "class"is omitted, the default value 7

 

is used.

 

 

<status>(num)

 

0

Call waiting service is not active

1

Call waiting service is active

<calling number>(str)

Phone number of waiting caller in the format specified by parameter <type of number>.

<type of number>(num)

Type of address octet in integer format (refer to GSM 04.08, subclause 10.5.4.7)

145

<calling number> includes international access code character '+'

AC75_ATC_V01.002

Page 237 of 569

10/30/06

Confidential / Released

 

 

Page 237
Image 237
Siemens AC75 manual Calling numberstr, Type of numbernum