AC75 AT Command Set

9.7 AT+CCWA

s

Examples

EXAMPLE 1

 

 

Parameter <n>

 

 

 

 

 

at+ccwa=1

To enable the presentation of the URC

 

OK

 

EXAMPLE 2

 

 

Parameter <mode>

 

 

 

 

 

at+ccwa=,1

To activate the supplementary service in the network for voice, data,

 

 

and fax calls (default classes).

 

 

Note that parameter <n> is left out. In this case, the current value of <n>

 

 

will be retained.

 

OK

To query the network status of call waiting for default classes

 

at+ccwa=,2

 

at+ccwa=1,1

Call Waiting is activated during voice calls.

 

at+ccwa=1,2

Call Waiting is activated during data calls.

 

at+ccwa=1,4

Call Waiting is activated during fax calls.

 

OK

 

EXAMPLE 3

 

 

Parameter <class>

 

 

 

 

 

AT+CCWA=,0,1

To deactivate call waiting for voice calls.

 

OK

 

AC75_ATC_V01.002

Page 239 of 569

10/30/06

Confidential / Released

 

 

Page 239
Image 239
Siemens AC75 manual At+ccwa=,1, At+ccwa=,2, At+ccwa=1,1, At+ccwa=1,2, At+ccwa=1,4, AT+CCWA=,0,1