3.3 AT^SIND s
AC75_ATC_V01.002 Page 85 of 569 10/30/06
Confidential / Released
3.3 AT^SIND Extended Indicator Control
Designed for extended event indicator control AT^SIND
offers greater flexibility than the standard command AT+CIND,
offers several extra indicators,
can show the current status of all indicators supported by AT+CIND and AT^SIND,
can be used to register or deregister the indicators of both commands,
displays all indicator event reports via "+CIEV" URCs.
Presentation mode of the generated URCs is controlled via AT+CMER.
The AT^SIND read command provides a list of all indicators supported by AT+CIND and AT^SIND. Each indica-
tor is represented with its registration mode and current value.
The AT^SIND write command can be used to select a single indicator in order to modify its registration and to
view the current value.
Syntax
Test Command
AT^SIND=?
Response(s)
^SIND: (<indDescr>, list of supported <indValue>s)[, (<indDescr>, list of supported <indValue>s)[,
...]], (list of supported <mode>s)
OK
Read Command
AT^SIND?
Response(s)
^SIND: <indDescr>, <mode>, <indValue>
^SIND: <indDescr>, <mode>, <indValue>, <eonsOperator>, <servProvider>
^SIND: <indDescr>, <mode>, <nitzUT>, <nitzTZ>, <nitzDST>
[^SIND: <indDescr>, <mode>, <indValue>]
...
OK
ERROR
+CME ERROR: <err>
Write Command
AT^SIND=<indDescr>, <mode>
Response(s)
^SIND: <indDescr>, <mode>, <indValue>
In case of: <indDescr>="eons" and <mode>=2
^SIND: <indDescr>, <mode>, <indValue>, <eonsOperator>, <servProvider>
In case of: <indDescr>="nitz" and <mode>=2
^SIND: <indDescr>, <mode>, <nitzUT>, <nitzTZ>, <nitzDST>
OK
ERROR
+CME ERROR: <err>
Reference(s) PIN ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge 4Last
SIEMENS - + + + + + + - + -