Ground Start Trunk (ZTN76)
The Ground Start Trunk Circuit Pack interfaces eight central office trunks and the TDM bus. Figure
●Ground detector circuit
●Port Input/Output (I/O) circuit
●Eight port circuits.
Ground Detector Circuit: The ground detector circuit determines if ground has been
applied to the tip lead for incoming seizure. It also senses tip | ground on outgoing seizure | |||||||||||
indicating | dial | tone is | present. | One ground sensor is used for | each | port circuit. Input for | ||||||
the | ground | sensor | comes | from the | port circuit as | an analog | current | to | the | |||
The | output | of | the | ground sensor | is | a port control | point to | the port | 1/0 | circuit. |
Port I/O Circuit: This circuit consists of bus expanders for communication between the
Port Circuits: The eight port circuits are identical.
coder/decoder (codec), hybrid circuit, line transformer, relay driver, and surge protection circuit.
The codec is a
The relay driver buffers and | inverts the relay drive | signals from the port 1/0 circuit so that |
a logic high input operates | the appropriate relay. | The relays control circuitry provides the |
proper signaling for ground start trunks. The trunks support