TABLE 3-B. Signaling Type Summary
SIGNALING | TRANSMIT |
| RECEIVE | ||
TYPE |
|
| |||
|
|
|
|
|
|
I Std. | grd | bat | open/bat | (*) | grd |
I Compat. | open/bat (*) | grd | grd |
| open/bat (*) |
V | open | grd | open |
| grd |
* An open circuit is preferred over voltage.
TABLE 3-C. TN760B Tie Trunk Preferred Signaling Formats
I N S T A L L A T I O N | S I T U A T I O N |
| PREFERRED SIGNALING FORMAT |
|
| |||||
|
|
|
|
| SYSTEM | 25 |
| FAR | END | |
| C I R C U M - |
|
| S I M P L E X |
| PROTECTED | S I M P L E X |
|
| PROTECTED |
FROM |
| T O |
|
|
|
| ||||
S T A N C E S |
| O R | S I G N A L | O R | O R | S I G N A L |
| O R | ||
|
|
|
| |||||||
|
|
|
| E & M | T Y P E | U N P R O T E C T E D | E&M | T Y P E |
| UNPROTECTED |
|
|
|
|
|
|
|
|
|
|
|
S25 | Co- |
| S25/S75 | Simplex | Type V | (Either) | Simplex | Type V |
| (Either) |
| Located |
|
|
|
|
|
|
|
|
|
S25 | Inter- |
| S25/S75 | Simplex | Type V | (Either) | Simplex | Type V |
| (Either) |
| Building |
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
S25 | Co- |
| S85 | Simplex | Type V | (Either) | Simplex | Type V |
| (Either) |
Located |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
S25 | Inter- |
| S85 | Simplex | Type V | (Either) | Simplex | Type V |
| (Either) |
| Building |
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
S25 | Co- |
| Dim. | E&M | Type I | Unprotected | E&M | Type I |
| Unprotected |
Building |
| Compatible | Standard | |||||||
|
|
|
|
|
|
| ||||
S25 | Inter- |
| Dim. | E&M | Type I | Protected | E&M | Type I |
| Protected |
| Building |
| Compatible | Standard | ||||||
|
|
|
|
|
|
| ||||
S25 | Co- |
| Other | E&M | Type I | Unprotected | E&M | Type I |
| Unprotected |
Located |
| Compatible | Standard | |||||||
|
|
|
|
|
|
| ||||
S25 | Inter- |
| Other | E&M | Type I | Protected | E&M | Type I |
| * |
| Building |
| Compatible | Standard |
| |||||
|
|
|
|
|
|
| ||||
S25 | Co- |
| Network | E&M | Type I | Unprotected | (Don't | (Don't |
| (Don’t |
Located |
| Interface | Standard | Care) | Care) |
| Care) |
* Requires a protection unit.
3 - 3 4