SYSTEM 25

CABINET

ZTN79

ATL

LINE CP

PART OF

OCTOPUS CABLE

— — — —

— — — —

C2

— — — —

— — — —

— — — —

PART OF SIP

SIP

ADAPT

I

C1

EXPOSED

CABLE

 

 

 

 

 

 

 

IROB

 

 

 

IROB

PROTECTION

 

 

 

PROTECTION

TII 341

 

 

 

TII 341

(NOTE 1)

 

 

 

(NOTE 1)

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

 

 

 

 

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

LEGEND :

B1

TYPICAL-103A CONNECTING BLOCK*

C1

–MODULAR CORD (D8W-87) - FURNISHED WITH SET

C2

–OCTOPUS

CABLE

(WP90780) - PEC 2720-05P

D – #

10 AWG

GROUND WIRE*

G

APPROVED

BUILDING GROUND

T1 – 7300H-TYPE VOICE TERMINAL

WI

– 4

PAIR

INSIDE

WIRING CABLE*

C1

VOICE

TERMINAL

T1 (NOTE 2)

NOTES :

1.IN-RANGE-OUT-OF-BLDG UNIT MODEL 341 IROB’S REQUIRED - PRIMARY/SECONDARY PROTECTORS.

2.RANGE: WITHIN 2000 FEET OF SYSTEM CABINET (LOCAL POWER REQUIRED >1000 FEET).

*FURNISHED BY INSTALLER

Figure 4-25. Out-Of-Building 7300H Series Multiline Voice Terminal

Connections

4-56

Page 391
Image 391
AT&T AT&T manual Ground Wire