Cisco Systems appendix Cisco Transport Manager Release 6.0 User Guide 78-16845-01

Models: 78-16845-01

1 138
Download 138 pages 47.51 Kb
Page 60
Image 60

Appendix J Troubleshooting

J.10.5 Configuration Center, Chassis View, Diagnostics Center, and Statistics Report Problems

Possible alternative workarounds:

1.Open a new GUI and a new Configuration Center, Chassis View, Diagnostics Center, or Statistics Report.

2.Use nmControl and perform "Resync Node," specifying the node ID.

J.10.5.4.2 Configuration Center, Chassis View, Diagnostics Center, or Statistics Report Does Not Show a Card, Line, or Port for a Node

Step 1 Check whether the node is synced up. This can be done by using the command selnd on the CTM CLI. Step 2 If the node has not synced up, wait for it to do so.

Step 3 If the node has synced up partially, check whether the card, line, or port is populated in the database. Refer to the Cisco Transport Manager Release 6.0 Database Schema.

Step 4 If the entry is not populated in the database, see J.10.4 Equipment Management Problems, page J-40.

Step 5 If the entry is present in the database, check the NMServer cache. This can be done by using the command nmControl on the CTM CLI. Check the nmControl.<pid>.dump

Step 6 If the element is not present in the NMServer cache, use nmClient and verify whether getChildren for FDN returns the entities in the nmClient.<pid>.dump file.

Step 7 If the element is present in the NMServer cache, open a new GUI and verify whether the missing elements are shown in it.

Defect Information—Collect the following information for further analysis:

topod.log, ILMITopoc.log, and NMServer.log

nmControl.dump

CMSCclient.log

Possible alternative workarounds:

1.Open a new GUI and a new Configuration Center, Chassis View, Diagnostics Center, or Statistics Report.

2.Use nmControl and perform "Resync Node," specifying the node ID.

J.10.5.4.3 Card, Line, or Port Information Is Incorrect on Configuration Center, Chassis View, Diagnostics Center, or Statistics Report

The entity information of an element shows incorrectly on the Configuration Center, Chassis View, Diagnostics Center, or Statistics Report.

Step 1 Check whether the node is synced up. This can be done by using the command selnd on the CTM CLI. Step 2 If the node has not synced up, then wait for it to do so.

Step 3 Check whether the card, line, or port is populated in the database. Refer to the Cisco Transport Manager Release 6.0 Database Schema.

Step 4 If the entry in the database matches the GUI, see J.10.4 Equipment Management Problems, page J-40.

Step 5 If the entry doesn't match the database, check the NMServer cache. This can be done by using the command nmControl on the CTM CLI. Check the nmControl.<pid>.dump.

Cisco Transport Manager Release 6.0 User Guide

 

J-60

78-16845-01

 

 

 

Page 60
Image 60
Cisco Systems appendix Cisco Transport Manager Release 6.0 User Guide 78-16845-01