Programming Function Blocks and Features

Custom algorithm prompts

Table 4-7 describes the custom algorithm prompts. See Table 4-2 for additional prompts. These prompts appear only if CUSTOM INPUT is enabled under FEATURES. See Section 0.

Table 4-7 Custom Algorithm Prompts

 

Prompt

 

 

Range/Selections

 

 

Definition

 

 

INPUT SIGNAL

 

 

EMF, TC, or RTD.

 

 

Selects the input hardware.

 

 

RJ ENABLE

 

 

Select YES for reference junction

 

 

Reference junction

 

 

 

 

 

compensation, NO for no

 

 

compensation.

 

 

 

 

 

compensation.

 

 

 

 

 

EMISSIVITY ENABLE

 

 

Select YES for emissivity

 

 

Emissivity compensation for

 

 

 

 

 

compensation for emf input.

 

 

emf input.

 

 

Xn

 

 

You must input at least 2 coordinates.

 

 

Use these prompts to plot a

 

 

 

 

 

X must increase by at least 0.00001.

 

 

curve of up to 20 points, where

 

 

 

 

 

Y values are not limited except in the

 

 

Xn is the incoming signal in

 

 

 

 

 

following 2 cases.

 

 

the electrical units selected

 

 

 

 

 

1. If the incoming signal is from a

 

 

and Yn is its corresponding

 

 

 

 

 

thermocouple and reference junction

 

 

value in the temperature units

 

 

 

 

 

 

 

selected. Interpolation is

 

 

 

 

 

compensation is on, make sure that

 

 

 

 

 

 

 

 

 

straight-line.

 

 

 

 

 

a, b, and c are all true.

 

 

 

 

 

 

 

 

 

 

 

 

Yn

 

 

a) All Y's are increasing or all are

 

 

 

 

 

 

 

 

decreasing.

 

 

 

 

 

 

 

 

b) Y range includes 0-65°C.

 

 

 

 

 

 

 

 

c) Temperature units are °F, °C, K,

 

 

 

 

 

 

 

 

or °R.

 

 

 

 

 

 

 

 

2. If Online adjustment of the value is

 

 

 

 

 

 

 

 

desired, make sure that all Y's are

 

 

 

 

 

 

 

 

increasing or all are decreasing.

 

 

 

 

 

ELECTRICAL UNITS

 

 

MV, OHMS, VOLTS

 

 

Units of the electrical signal.

 

 

 

 

 

 

 

 

 

 

 

LAG

 

 

0 seconds or OFF

 

 

LAG is a time constant applied

 

 

 

 

 

 

 

 

to the input measurement

 

 

 

 

 

 

 

 

value. This provides digital

 

 

 

 

 

 

 

 

filtering (LAG) to the

 

 

 

 

 

 

 

 

measurement.

 

 

 

 

 

 

 

 

Lag appears on menu only if

 

 

 

 

 

 

 

 

EXPANDED INPUT is enabled

 

 

 

 

 

 

 

 

under Enable Features in the

 

 

 

 

 

 

 

 

Program menu.

 

 

SAMPLE HOLD

 

 

OFF, discrete parameter, 0, 1

 

 

Holds Input. The input value is

 

 

 

 

 

 

 

 

measured normally when this

 

 

 

 

 

 

 

 

discrete is OFF(0) and holds

 

 

 

 

 

 

 

 

its last value when the discrete

 

 

 

 

 

 

 

 

is ON(1).

 

 

 

 

 

 

 

 

Hold appears on menu only if

 

 

 

 

 

 

 

 

EXPANDED INPUT is enabled

 

 

 

 

 

 

 

 

under Enable Features in the

 

 

 

 

 

 

 

 

Program menu.

 

Press Menu when entries are complete. At the prompt "PRESS ENTER TO SAVE", press Enter to save your changes, or press Menu again to exit the session without saving the changes.