Honeywell VRX180 user manual Connecting the RS422/485 link to a computer, Arrangement Description

Models: VRX180

1 294
Download 294 pages 53.02 Kb
Page 47
Image 47

Installation

2.5.7.4 Connecting the RS422/485 link to a computer

The VRX180 video recorder with the RS422/485 Communications option can be connected your computer using one of two arrangements :

Wired to an RS422/485 compatible serial port (if the computer is equipped with such a port).

Wire the RS232 serial port of the computer to an RS232 to RS485 converter. The RS485 port of the converter should be wired to the Communications port of the VRX recorder.

Arrangement

Description

ICS plug-in I/O board

Wired directly to the RS422/485 port in your computer using an ICS plug-

 

in I/O board which is specifically designed to interface with the IBM (or

 

IBM compatible) PC, PC/XT; or PC/AT computer.

 

This board is available from...

 

ICS Computer Products, Inc.

 

5466 Complex Street

 

Suite 208

 

San Diego, California 92123

Burr-Brown Converter

Using the RS232 port a Burr-Brown RS232 to RS422/485 converter

 

installed between the RS232 port and the video recorder.

 

This converter is available from :

 

Burr-Brown

 

International Airport Industrial Park

 

P.O. Box 11400

 

Tucson, Arizona 85734

 

Part number LDM485ST, limited distance modem

Westermo converter

The Westermo MA44 converts RS232 to RS422/485. It is installed

 

between the RS232 port and the video recorder.

2.5.7.5 Rear connection

The video recorder has built in circuits to reduce the effects of most electrical noise. We recommend that you review the following guidelines, to minimize the noise effects.

1.Separate the communication leadwires from the line voltage, the alarm output, contactors, motors etc...

2.For a communication distance, over 1.5 meters, use a separate metal tray, or metal conduit.

3.Use wiring cable composed of twisted pair wirings, with a shield for RS485 and RS422. Use a shielded cable for RS232.

4.Connect the shield wire to the ground, at one end only, preferably at the video recorder. Use for example a wiring cable type: Belden 9271 twinax, or equivalent.

5.We recommend to install a 120 ohms resistor between TXA and TXB, on the last video recorder on communication link.

6.The maximum capabilities are:

Type of communication

Distances max.

# of Unit

RS232

15 meters / 50 feet

1

RS422

1000 meters / 3280 feet

15

RS485

1200 meters / 4000 feet

31

Video Recorder - User Manual

33

Page 47
Image 47
Honeywell VRX180 user manual Connecting the RS422/485 link to a computer, Arrangement Description, Rear connection