Diagnostic and error messages

 

 

 

 

 

 

 

 

Table 9-2 Internal Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

Error message

 

 

 

Suggested Action

 

 

 

 

 

 

 

 

 

 

 

 

SLOT CARD FAILURE

 

 

1. Check for noise.

 

 

 

 

 

 

2.

Check AI card connection.

 

 

 

 

 

 

3.

Replace AI card.

 

 

 

 

 

 

 

 

 

 

 

 

STORAGE FAILURE

 

 

1. Check for bad floppy disk.

 

 

 

 

 

 

2.

Run disk diagnostic on the disk drive.

 

 

 

 

 

 

3.

Check seating of floppy cables.

 

 

 

 

 

 

4.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

DATA STORAGE STATUS

 

 

1. Check for bad floppy disk.

 

 

 

 

LOST

 

2.

Run disk diagnostic on the disk drive.

 

 

 

 

 

 

 

 

 

 

 

 

3.

Check seating of floppy cables.

 

 

 

 

 

 

4.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

RJ FAILURE

 

 

1. Check reference junction sensor connection.

 

 

 

 

 

 

2.

Check AI card.

 

 

 

 

 

 

3.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

CLOCK FAILURE

 

 

1. Reprogram clock.

 

 

 

 

 

 

2.

Reset unit.

 

 

 

 

 

 

3.

Change lithium battery on interconnection board.

 

 

 

 

 

 

4.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

CLOCK RESET

 

 

1. Reprogram clock.

 

 

 

 

 

 

2.

Reset unit.

 

 

 

 

 

 

3.

Change lithium battery on interconnection board.

 

 

 

 

 

 

4.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

TIMING ERROR

 

 

1. Reprogram clock.

 

 

 

 

 

 

2.

Reset unit.

 

 

 

 

 

 

3.

Change lithium battery on interconnection board.

 

 

 

 

 

 

4.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

TASK ERROR

 

 

1. Reset unit.

 

 

 

 

 

 

2.

Clear configuration and reload.

 

 

 

 

 

 

3.

If message recurs, replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

RAM ERROR

 

 

1. Run RAM diagnostic.

 

 

 

 

 

 

2.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

 

COMM PORT ERROR

 

 

1. Check communications card seating.

 

 

 

 

 

 

2.

Replace communications card.

 

 

 

 

 

 

3.

Replace CPU.

 

 

 

 

 

 

 

 

 

 

 

Video Recorder – User Manual