Introduction

Model Selection Guide (cont.)

 

 

 

 

 

 

 

VRX180

TABLE V - OPTIONS (continued)

 

 

Selection

Approvals

 

CE Mark Compliant

 

 

_ _ _ 0 _ _

 

 

 

CSA/NRTLc/CE Mark

 

 

_ _ _ C _ _

 

Software

 

None

 

 

 

_ _ _ _ 0 _

 

 

 

SDA and SCF

 

 

_ _ _ _ B _

 

 

 

SCF (Configuration Software)

 

 

_ _ _ _ C _

 

 

 

SDA (Data Analysis Software)

 

 

_ _ _ _ E _

 

Case

 

Galvanized Case, Grey Door, Glass Window, Latch

_ _ _ _ _ 0

 

 

 

Galvanized Case, Grey Door, Glass Window, Key Lock

_ _ _ _ _ 1

 

 

 

Galvanized Case, Grey Door, Plastic Window, Latch

_ _ _ _ _ 2

 

 

 

Galvanized Case, Grey Door, Plastic Window, Key Lock

_ _ _ _ _ 3

 

 

 

Portable Case (Painted Case, Handles)

 

_ _ _ _ _ 6

 

TABLE VI

 

 

 

 

 

 

 

 

Factory Use Only

 

 

 

 

 

 

00

 

SOFTWARES AND SUPPORT PARTS

 

 

Part #

SDA Data Analysis Software (can be ordered separately if not selected in Table V)

045501

 

SCF Configuration Software (can be ordered separately if not selected in Table V)

045502

 

SDI Disk Initialization Software

(Note 6)

 

 

46193351-501

 

Kit of 4 resistors 250 Ohms for 4-20 mA input

 

 

46181080-503

 

RESTRICTIONS

 

 

 

 

 

 

 

 

Restriction Letter

 

 

 

Available With

 

Not Available With

 

Table

 

Selection

Table

Selection

c

 

 

 

 

II

_ _ _ _ _ A, _ _ _ _ _ B, _ _ _ _ _ C,

 

 

 

 

 

 

_ _ _ _ _ E, _ _ _ _ _ R, _ _ _ _ _ G,

 

 

 

 

 

 

_ _ _ _ _ H, _ _ _ _ _ M

Notes:

1.The available algorithms include: PID (standard and advance), Cascade, Split Output and On/Off. The appropriate outputs from Table I must be specified - Current or Relays.

If Split (Duplex) output Control is required, advance math must be selected ( Table III ).

2.Standard Math includes 24 Calculated Values and the following pre-packaged algorithms

Free Form Math

Logic Operators

Flip-Flop/One Shot

Periodic Timer

Free Form Logic

Math Operators

Invertor

 

Advance Math includes 64 Calculated Values and the following additional of pre-package algorithms.

Signal Select

Interval Timer

Counter

 

Compare

Relative Humidity

Scaling

 

Signal Clamp

Mass Flow

Advanced Splitter

 

Peak Picking

Fo Calculation

Continuous Emissions Monitoring

Function Generator

Multiple Input Average

-

CEM Block Average

 

Carbon Potential

Single Point Average

-

CEM Rolling Average

 

Rolling Average

Standard Splitter

 

 

 

3.Customer must supply Input Actuation Type and Range for each input for inclusion in the free form section of the Factory order to supply the Custom Calibration Certificate, otherwise the calibration will be based on the factory default ranges.

4.When selecting SP program make sure to select analog output (current) as necessary (Table II slot N,P).

5.When selecting Control loops, make sure to select outputs (as necessary in Table II)

6.Provided with each VRX180 are : one pre-initialized disk and one SDI software pack. SDI software should be installed on a PC and used for initialization of new disks.

7.Must purchase Table II _ _ _ _ M _ in order to select Table II Selection _ _ _ _ _ M.

12

Video recorder – User Manual

Page 26
Image 26
Honeywell VRX180 user manual Softwares and Support Parts