Table 1-1 Specifications (continued)

Analog input accuracy and rated limits

Accuracy

Reference conditions

Temperature = 23°C ±

2°C (73°F ± 3°F)

 

 

Humidity = 65% RH ±

5%

 

 

 

 

Line voltage = Nominal ±

1%

 

 

 

Source resistance = 0 ohm

 

 

Series mode and common mode = 0 V

 

 

Frequency = Nominal ± 1%

 

Accuracy

Field calibration accuracy 0.05% of the selected range (IEC 873)

 

 

Factory calibration: 0.1%

 

 

 

 

Cold junction accuracy: ±

0.5°C

Rated limits and

Parameters

Rated limits

 

 

Influence on accuracy

associated drifts

 

 

 

 

 

 

Temperature

0 to 50°C (32 to 120 °F)

 

0.15% per 10°C of change (See

 

 

 

 

 

Note A)

 

 

 

 

 

Cold junction 0.3°C/10°C

 

Supply voltage

85 to 250 V

 

 

No influence

 

Source resistance

T/C, mV

 

 

6 µV per 400 Ohms of line

 

 

 

 

 

resistance max. = 1000 Ohms

 

 

 

 

 

 

 

 

RTD

 

 

0.1°C per Ohm in each wire

 

 

 

 

 

balanced leads

 

 

 

 

 

40 Ohms max. (from 0 to 400°C)

 

Humidity

10 to 90% RH at 25°C

 

 

0.1% max.

 

Long-term stability

 

 

 

0.1% per year

Table 1-2 Analog Input Accuracy--Linear types

 

Millivolts

 

 

Volts

 

 

Current

 

 

Ohms

 

 

0 to 10 mV

 

 

0 to 1 V

 

 

0, 20 mA

 

 

0 to 200

 

 

-10, +10 mV

 

 

-1, 0, 1 V

 

 

4, 20 mA

 

 

0 to 2000

 

 

0 to 20 mV

 

 

0 to 2 V

 

 

 

 

 

 

 

 

-20, 0, +20 mV

 

 

-2, 0, +2 V

 

 

 

 

 

 

 

 

0, 50 mV

 

 

0 to 5 V

 

 

 

 

 

 

 

 

-50, 0, +50 mV

 

 

-5, 0, +5 V

 

 

 

 

 

 

 

 

10 to 50 mV

 

 

1 to 5 V

 

 

 

 

 

 

 

 

0 to 100 mV

 

 

0 to 10 V

 

 

 

 

 

 

 

 

-100, 0, +100 mV

 

 

-10, 0, +10 V

 

 

 

 

 

 

 

 

0 to 500 mV

 

 

 

 

 

 

 

 

 

 

 

-500, 0, +500 mV

 

 

 

 

 

 

 

 

 

 

NOTE:

- The mA inputs must be connected to a 250 ohms resistor across the input terminals.