Honeywell VRX180 user manual Off-line Diagnostics, Calibrate Analog Output Procedure Step Action

Models: VRX180

1 294
Download 294 pages 53.02 Kb
Page 261
Image 261

Maintenance

WARNING

Disconnect power to all terminals before connecting or disconnecting calibration leads. Hazardous voltage is present on the mains terminals and may be present on other terminals. More than one switch may be required to de-energize the unit before servicing.

Failure to comply with these instructions could result in death or serious injury.

NOTICE

Time-stamp and description of successful calibrations are stored to disk in the Event file.

 

 

 

 

Table 8-2 Calibrate Analog Output Procedure

 

 

Step

 

 

Action

 

 

 

 

 

 

 

 

1

 

Connect the meter to the output #1 terminals.

 

 

 

 

 

 

 

2

 

Select CALIBRATE ANALOG OUTPUTS.

 

 

 

 

 

 

 

 

3

 

 

Select OUTPUT #1 LOW. The menu will disappear and the meter will read approximately 4 mA

 

 

 

 

 

(CAT).

 

 

 

 

 

 

 

 

4

 

 

Use the Increment and Decrement buttons to adjust the meter reading to the exact low value 4 mA.

 

 

 

 

 

Press Enter when done.

 

 

 

 

 

 

 

 

5

 

 

Select OUTPUT #1 HIGH. The menu will disappear and the meter will read approximately 20 mA

 

 

 

 

 

(CAT).

 

 

 

 

 

 

 

 

6

 

 

Use the Increment or Decrement buttons to adjust the meter reading to the exact high value. Press

 

 

 

 

 

Enter when done.

 

 

 

 

 

 

 

 

7

 

 

Repeat steps 1-6 to calibrate other CAT outputs.

 

 

 

 

 

 

 

8

 

Press Menu to restore the main Maintenance menu.

 

 

 

 

 

 

 

8.6 Off-line Diagnostics

The following table describes the prompts.

 

 

 

 

Table 8-3 Offline Diagnostic Prompts

 

 

Prompt

 

 

Function

 

 

 

 

 

 

 

 

RAM SIZE (KB)

 

 

Shows amount of RAM found during power-up self-test. If less than 3072KB,

 

 

 

 

 

replace the CPU.

 

 

 

 

 

 

 

 

KEYBOARD TEST

 

 

Select this to verify operation of each key. When each key is pressed, its name

 

 

 

 

 

should appear onscreen. An AT keyboard can also be tested if connected.

 

 

 

 

 

 

 

 

DISPLAY TEST

 

 

Select this then press Enter to test each display color: red, green, blue, white,

 

 

 

 

 

black. Any failed display pixels should be apparent.

 

 

 

 

 

 

 

 

DISK READ/WRITE TEST

 

 

Select this to verify read/write disk function.

 

 

 

 

 

 

 

Video Recorder – User Manual