Programming Function Blocks and Features

4.4 Frequently used programming prompts

When programming the instrument you will see certain prompts repeatedly in different menus. These are described in Table 4-2, rather than in each menu in which they appear.

Table 4-2 Frequently Used Programming Prompts

Prompt

 

 

 

Range/Selections

 

 

 

 

Definition

 

IN DECIMAL POS

 

 

X.XXXXX

 

XXXX.XX

 

 

 

 

Select the decimal point position to be

 

 

 

 

XX.XXXX

 

XXXXX.X

 

 

 

 

used for all inputs to the function.

 

 

 

 

XXX.XXX

 

XXXXXX.

 

 

 

 

Select X.XXEXX to display the function’s

 

 

 

 

 

 

X.XXEXX

 

 

 

 

values in exponential notation.

 

 

 

 

 

 

 

 

 

 

Example: 1.23E4 means 1.23 x 104 .

 

 

 

 

 

 

 

 

 

 

 

 

OUT DECIMAL POS

 

 

Same as IN DECIMAL POS selections

 

Select the decimal point position that will

 

 

 

 

 

 

 

 

 

 

 

be used for all outputs of the function.

 

ON LABEL*

 

 

OFF

ON

FILL

DRAIN

 

 

Select the discrete function’s ON(1)

 

 

 

 

UP

DOWN

EMPTY

FULL

 

 

state label.

 

 

 

 

START

STOP

IN

OUT

 

 

 

 

 

 

 

LOW

HIGH

OPEN

CLOSED

 

 

 

 

 

 

 

RESET

RUN

HOLD

ACTIVE

 

 

 

 

 

 

 

TRUE

FALSE

READY

ABORT

 

 

 

 

 

 

 

LEFT

RIGHT

ALARM

NORMAL

 

 

 

 

 

 

 

DECRS

INCRS

AUTO

MANUAL

 

 

 

 

 

 

 

LOAD

UNLOAD

SP1

SP2

 

 

 

 

 

 

 

COOL

HEAT

NO

YES

 

 

 

 

 

 

 

 

 

PAUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF LABEL*

 

 

Same as ON LABEL selections

 

 

 

 

Select the discrete function’s OFF state

 

 

 

 

 

 

 

 

 

 

 

label.

 

DESCR*

 

 

Enter up to 16 characters.

 

 

 

 

Usually appears as a header or title on

 

 

 

 

 

 

 

 

 

 

 

some displays and reports. For alarms,

 

 

 

 

 

 

 

 

 

 

 

this is the actual alarm message.

 

 

 

 

 

 

 

 

 

 

TAG*

 

 

Enter 7 characters maximum.

 

 

 

Identifies the point or function on most

 

 

 

 

 

 

 

 

 

 

 

displays and reports. Each tag must be

 

 

 

 

 

 

 

 

 

 

 

unique.

 

UNITS*

 

 

Default choices:

 

 

 

 

 

Shows units of measure for analog

 

 

 

 

PSI

DEGR

GAL

MA

 

 

values on most displays and reports.

 

 

 

 

BAR

K

LPH

%

 

 

 

These 25 choices can be changed. See

 

 

 

 

 

 

 

Table 4-4.

 

 

 

 

MW

MV

LPM

PH

 

 

 

 

 

 

 

 

 

 

 

 

 

GPH

V

LPS

KG

 

 

 

 

 

 

 

GPM

OHM

LITR

GRAM

 

 

 

 

 

 

 

GPS

HZ

DEGC

LB

 

 

 

 

 

 

 

 

 

DEGF

 

 

 

 

 

 

* Prompt does not appear if labeling is disabled under ENABLE FEATURES.