Language Reference
ADAPBPCTL Performs trace math A * DL / (A + B + C) 7 A with each sweep.
|
| Item |
|
| Description |
| Preset State |
| ADAPBPCTL | OFF | |
Example | 120 | OUTPUT | 723;"SNGLS;" | Activate | |
| 130 | OUTPUT | 723;"LN;" | Select linear amplitude scale . | |
| 140 | OUTPUT | 723;"TS;VIEW TRA;" | Sweep trace A and store it. | |
| 150 | OUTPUT | 723;"ADAPBPCTL ON;" |
|
Description The ADAPBPCTL command requires a linear display mode. It multiplies trace A by the display line and divides the result by the sum of traces A, B, and
C. The results are stored in trace A. If trace A is in
This command allows ratio measurements to be made as a sweep is taken. If trace B has points near the bottom of screen, overow or poor precision can occur. If a division by zero is attempted, a division by the smallest representable value will be performed instead.
To ensure that correct data is displayed, be sure that a sweep is taken before using this command. Only one trace math operation may be active at any given time.