6.4 Replacing the Maintenance Kit D (Separation Charger Unit)
4 | Hold the new separation charger unit so that the projecting pin is in front of you and |
| pass the green knob (separation charger wire cleaning knob) through the secondary |
transfer unit. Press the back side to lock the unit.
| Green knob (Separation Charger |
| Wire Cleaning Knob) |
Figure | |
5 | Push the paper feed unit back in completely and close the front cover. |
Paper Feed Unit
Figure
6 | Use the operator panel to reset the counter. Press the MENU key. Press the [U] or | |||
| [V] key repeatedly until Others > appears. | |||
|
|
|
|
|
|
| Others | > |
|
|
|
|
|
|