PRESCRIBE FRPO D0 Command
H4: Parity
| Parameter value | Meaning | 
| 0 | None | 
| 1 | Odd | 
| 2 | Even | 
| 3 | Ignored | 
The factory setting is 0 (none).
H5: Protocol logic
| Parameter value | Meaning | 
| 0 | Combination of DTR (positive logic) and XON/XOFF | 
| 1 | DTR (positive logic) | 
| 2 | DTR ( negative logic) | 
| 3 | XON/XOFF | 
| 4 | ETX/ACK | 
The factory setting is 0.
H6: Buffer 
A percentage value from 0 to 99. The factory setting is 90.
H7: Buffer nearly-empty  threshold
A percentage value from 0 to 99. The factory setting is 70. The factory settings of the buffer 
The difference between the 
H8: Received data buffer size
The input buffer size is specified in increments of 100 kB. The factory setting is 5 (500 kB).
B.3.2 PRESCRIBE FRPO D0 Command
The PRESCRIBE FRPO D0 command is provided to allow manipulating XON/XOFF when an error has occurred on the serial interface. Table 
| Timing of XON transfer to | Serial interface error | |
| host while Ready or Waiting | error not handled | error handled | 
| 
 | 
 | 
 | 
| XON sent every  | D0=0 (default) | D0=1 | 
| 
 | 
 | 
 | 
| XON not sent | D0=10 | D0=11 | 
| 
 | 
 | 
 | 
Table 