Installing the LCS60

comment

A description of the entry.

hardware type

The fiber interface hardware for the LCS60 always con-

 

nects to the CPM-HS.

connect-time

Specifies if billing information is to be logged.

number of channels

Enter 512.

connect time billing

This is not used for the LCS60.

Single or multiple

Enter single.

group

Enter the group from the previous operation.

Endpoint

This is not used for the LCS60.

restore

The CPM-HS module must be restored to service before

 

it can be used.

Power and Grounding

Connect the AC power cord provided to a three-wire grounded 110 VAC receptacle and the LCS60 rear panel power receptacle as shown in Figure 2-7.

Connect DC power as shown in Figure 2-7.

Hardware

Power-Up Procedures

Follow the steps below for LCS60 power up only after reading this section.

1. Connect the LCS60 to the power source. For the AC power unit, the outlet should be on a dedicated circuit for the LCS60.

2. Power up the system console. (Refer to the section Connecting the System Console.) If the system console is connected to the LCS60 by means of a data switch network, enter the appropriate console name (entered in Screens 2-1 or 2-2) in response to the DESTINATION prompt.

3. Power up the LCS60 by turning the on/off switch to on.

Issue 3