Error Messages

 

switch. Try manually restarting the interface.

RX-MUTE

The optical connection between the receiver on the VMEDKHS

 

board in the LCS60 and the transmitter on the CPM-HS paddle

 

board at the data switch has been broken. Verify that the CPM-

 

HS is properly installed in the data switch slot and that there is

 

optical connectivity between the LCS60 and the CPM-HS. The

 

interface will recover automatically when the condition has been

 

cleared.

TX-HANG

The transmitter on the VMEDKHS board in the LCS60 has

 

stalled and is no longer able to send data to the data switch net-

 

work through the CPM-HS. Verify that the CPM-HS is properly

 

installed in the data switch slot and that there is optical connec-

 

tivity between the LCS60 and the CPM-HS. Also verify that the

 

CPM-HS is in service. The interface will recover automatically

 

when the condition has been cleared.

TX-FULL

The transmitter on the VMEDKHS board in the LCS60 has

 

apparently stalled and data is no longer draining to the data

 

switch network through the CPM-HS. This condition should be

 

detected as a TX-HANG error unless the administrator has dis-

 

abled stall detection by modifying dkhs tunable parameters. Try

 

manually restarting the interface.

dkhs0: Interface Restarted

This message indicates the interface has automatically restarted after a previ- ously detected error.

NOTICE: dkhs0: Hardware Reset Failed

This message indicates that an attempt to reset the board by means of the dkmaint command has failed.

If an error message is received, the administrator should check the CPM-HS module, hardware, and fiber link connections, and execute the dkmaint com- mand to reset the interface.

Administration

Issue 3

8-43

Page 227
Image 227
HP LCS60 Switch. Try manually restarting the interface, Optical connection between the receiver on the Vmedkhs, Cleared