Alarms to StarKeeper II NMS

L600610 Interface to <interface id> is down. (reason: n)

Description: The LCS60 is not able to transmit data over the specified interface.

Reason code 1: Loss of carrier detected for the physical Ethernet interface.

Action: The recommended action for reason code 1 is as follows. Verify the connection of the Ethernet interface to the LCS60 and verify the physical state of the Ethernet network. The LCS60 does not need to be rebooted when the physical connection is reestablished.

L600625 Process lcm is down.

Description: The lcm process is not executing.

Action: Restart the LCM by executing lcsadm -c manager start on the system con-

sole. If the problem occurs again, reboot the system from the console using: cd / ; /etc/shutdown -y-g0-i6.

Call your LCS60 support personnel if the problem persists.

L600630 Process routed is down.

Description: The routed process is not executing.

Action: Restart the routed process by executing lcsadm -c start routed from the LCS60 system console.

Call your LCS60 support personnel if the problem persists.

L600635 Process inetinit is down.

Description: The inetinit process is not executing.

Action: Reboot the system (cd / ; /etc/shutdown -y -g0 -i6).

Note: Anytime the inetinit processs goes down, the system must be rebooted, even if a message is displayed that inetinit is back up.

Call your LCS60 support personnel if the problem persists.

NMS II StarKeeper

Issue 3

B-7