Installing the LCS60

Hardware

Dialogues

Note: Dialogues differ depending on the data switch and release.

Enter Group Name

CC0> enter group

GROUP [up to 8 chars]: morse

TYPE [local, trunk: +(local)]: local

DIRECTION [originate, receive, 2way]: 2way

DEVICE OR HOST [up to 8 chars]: morse

PASSWORD [up to 8 chars, none: +(none)]:none

ROUND ROBIN SERVICE [per_port, per_module, none: +(none)]: none

GROUP [up to 8 chars]: Delete

CC0>

Conduct the appropriate dialogue as shown in screen above. (Enter Delete to end the session.) The entries are described below:

group

Defines the group name by which the data switch knows the

 

LCS60. This is morse in the example. This must be the same as

 

the LCS60 node name.
type

The LCS60 is a local connection to the data switch (the CPM-HS

 

module resides in this data switch).

direction

The fiber interface may be used to originate and receive calls

 

through the CPM-HS module, therefore, it is 2way.

device/host

We recommend the name be the same as the name of the LCS60.

password

Passwords are not used with the CPM-HS module.

round robin

Choose the default of none.

Define the Local Address for the LCS60

Note: You must enter an address for each IP Network Security group on the node with a group name of the default node.

Conduct the appropriate dialogue as shown in the screen below.

2-22

Issue 3