StarKeeper II NMS

Configuration of the StarKeeper II NMS

20. To exit the selection menu, press Return and enter yes at the Exit the Menu program? prompt.

21. At the SK: prompt, enter conn_sync.

Alarms to StarKeeper II NMS

Once you have configured the StarKeeper II NMS to monitor the LCS60, the alarms listed in this section will be sent from the LCS60 to the StarKeeper II NMS. If the condition that generated an alarm corrects itself, StarKeeper II NMS will automatically clear the alarm.

Alarms transmitted to StarKeeper II NMS are not accompanied by the display of corresponding user messages on the system console of the LCS60. The data switch controller detects the loss of the LCS60's CPM-HS module and sends the alarm to StarKeeper II NMS. The StarKeeper II NMS detects loss of connectivity to an LCS60 for Ethernet. (Refer to the StarKeeper II NMS Graphics User Guide for details on StarKeeper II NMS alarms.)

L600600 LCS60STATD process exiting.

Description: The lcs60statD process has terminated execution.

Action: None required. StarKeeper II NMS will report a link-down condition for the LCS60 within several minutes of receiving this message, it will then attempt to reestablish connection to the LCS60. The lcs60statD process will automatically be restarted when the connection is reestablished.

B-6

Issue 3

Page 286
Image 286
HP LCS60 manual Alarms to StarKeeper II NMS