Hardware Management Overview—MPCBL0010 SBC

Table 111. OEM Event/Reading Type

OEM Name

OEM Number

Description

 

 

 

OEM Firmware Information 1

70h

Internal diagnostic data.

 

 

 

OEM Firmware Information 2

75h

Internal diagnostic data.

 

 

 

OEM Power Good

77h

Discrete sensor indicates power good status.

 

 

 

10.3System Event Log (SEL)

MPCBL0010 SBC IPMC events are logged and stored in non-volatile memory on the AdvancedTCA shelf manager. There is no local SEL on the MPCBL0010 SBC. The SBC IPMC sends events to the AdvancedTCA shelf manager to ensure that post-mortem logging information is available should a failure occur that disables the SBCs processor. Events are forwarded to the shelf manager and logged to the SEL as required in the AdvancedTCA specification.

Table 112. SEL Events Supported (Sheet 1 of 5)

 

Sensor

Sensor

 

 

Sensor Type

Type

Specific

Event

Description

 

Code

Offset

 

 

 

 

 

 

 

Reserved

00h

-

Reserved

Reserved

 

 

 

 

 

Temperature

01h

-

Temperature

Temperature reading exceeds thresholds.

 

 

 

 

 

Voltage

02h

-

Voltage

Voltage reading exceeds thresholds.

 

 

 

 

 

Current

03h

-

Current

Current reading exceeds supported

thresholds.

 

 

 

 

 

 

 

 

 

Platform Security

 

01h

Pre-boot password violation - user

Password check failed.

06h

password

 

 

Violation Attempt

 

 

 

 

04h

Other pre-boot password violation

Password check failed.

 

 

 

 

 

 

 

 

 

00h

IERR

Processor IERR has occurred.

 

 

 

 

 

 

 

01h

Thermal Trip

Processor thermal trip has occurred.

 

 

 

 

 

 

 

04h

Initialization Failure

Processor did not start.

 

 

 

 

 

Processor

07h

06h

SM BIOS uncorrectable CPU-

Uncorrectable error.

 

 

complex error

 

 

 

 

 

 

 

 

 

 

 

07h

Processor Presence Detected

Indicates processor is present.

 

 

 

 

 

 

 

0Ah

Processor Automatically Throttled

Processor started throttling due to

 

 

excessive temperature.

 

 

 

 

 

 

 

 

 

 

 

00h

Presence Detected

Power feed presence (not enabled by

Power Supply

08h

default).

 

 

 

 

 

 

 

01h

Power Supply Failure Detected

Fuse failure detected.

 

 

 

 

 

Unit Based (Power)

0Bh

-

Power (Watts)

Power (watts) reading exceeds supported

threshold.

 

 

 

 

 

 

 

 

 

 

 

00h

Correctable ECC

Correctable ECC memory error has

 

 

occurred.

Memory

0Ch

 

 

 

 

 

01h

Uncorrectable ECC

Uncorrectable ECC memory error has

 

 

 

 

occurred.

 

 

 

 

 

 

 

 

 

POST Memory Resize

0Eh

-

Generic Discreet Reading Type

Indicates if CMOS memory size is wrong.

 

 

 

 

 

 

Intel NetStructure® MPCBL0010 Single Board Computer

October 2006

Technical Product Specification

Order Number: 304120

121

Page 122
Image 122
Intel MPCBL0010 manual System Event Log SEL, OEM Event/Reading Type, SEL Events Supported Sheet 1