MPCBL0010 SBC—Operating the Unit
Intel NetStructure® MPCBL0010 Single Board Computer
Technical Product Specification October 2006
36 Order Number: 304120
# ipmitool fwum download <IPMI FW file>.bin
# ipmitool fwum upgrade <IPMI FW file>.bin
4. To verify that the upgrade worked properly, run the following command:
# ipmitool fwum status
The output of this command should show the “last known good” version to be
the same as the version just upgraded to. The “previous good” version
should show the previous version before the upgrade.
5. To roll back the lat upgraded version, run the following command:
# ipmitool fwum rollback
Note: You can also use Get Device ID IPMI to verify the current reported version of the
IPMI firmware.
3.9 Digital Ground to Chassis Ground Connectivity
The default grounding for the MPCBL0010 SBC is that digital ground is isolated from the
chassis ground. To connect the digital ground to the chassis ground, install a stainless
steel M2.5 x 6 Phillips pan head screw into the hole next to the AdvancedTCA K1
alignment block (circled in red in Figure 9) on the MPCBL0010 SBC. The screw must be
tightened to 4 lb. per in.
Note: Digital ground is also called logic ground. Chassis ground is also known as shelf ground.
Figure 9. Digital Ground and Chassis Ground Isolated (Default)